Pular para o conteúdo principal
GE Healthcare · CTLightSpeed2600074295026726000742850359

LightSpeed 5.X (80/100kW)

Symptom

Customer sees "Detector Temperature Is High. Image quality may be affected". Customer sees Detector Temperature Is High. Image quality may be affected

Error message

Error: 260007429 WARNING: Data Acquisition System Temperature is nearing the Upper Limit. See long description for a full sample error message. Wed Jul 16 06:39:30 2008 Error: 260007429 Host: DAS Process: DCB Firmware File: ctemptst.c Line: 584 Function: DATA ACQUISITION : Scan Data Acquisition Scan: 50267/8/56 Type: Axial Exception Level: Pri/Soft Time: 06:39:30:680 Log Series: 779 WARNING: Data Acquisition System Temperature is nearing the Upper Limit.

Error: 260007428 WARNING: DAS Temperature is nearing the Upper Limit. See LD for more details Mon Aug 28 06:39:06 2006 Error: 260007428 Host: orp Process: orp_subsys File: ctemptst.c Line: 600 Mon Aug 28 06:39:04 2006 Host : Das Ermes # : 260007428 Exception Class : Soft Severity : Sec/Soft File : ctemptst.c Line# : 600 Function : No System Function Reported Scan Type : None/Unknown Scan: 50359/1/0 WARNING: DAS Temperature is nearing the Upper Limit. Highest temperature was seen is on Converter Board 23. Measured: 63.0 degrees C. Acceptable Range: 15.0 to 62.0 degrees C. See Following Error Message for Converter Card List

Applies to

Models
LightSpeed
Product
LightSpeed 5.X (80/100kW) LightSpeed 5.X (80/100kW) ~ Use with both MDAS and GDAS ~ GRE Console HP_H_G16 HP_H_M16 HP_O_M16 LightSpeed 5.X (100kW) GDAS16 with GRE Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare CT issues