LightSpeed 4.X - GRE

Symptom

Scanner Hardware Stopped Scan. Scanner Hardware Stopped Scan

Error message

Error: 214343 MA out of WARNING tolerance Mon Jan 26 20:19:25 2009 Error: 214343 Host: OBC Process: Diag Exec File: technic_monitor.c 1.40 Line: 1680 Function: Diagnostics XRAY GENERATION : MA Loop Test Name: XRay - Manual Unique ID: 16015 Iteration: 1 Exc. Level: Soft Time: 21616 Error Type: Hardware MA out of WARNING tolerance. Selection: 80KV 40mA MA loop=1 (0=Open 1=Closed) Tolerance: Upper=42.0mA Lower=37.9mA Total samples: 11 . Samples Aver mA . Aver mA Above Tol Above Tol below Tol Below Tol ----------------------------------------------------------------- Anode 37.5mA 0 0.0mA -- -- Function: Diagnostics XRAY GENERATION : MA Loop Test Name: XRay - Manual Unique ID: 16349 Iteration: 1 Exc. Level: Soft Time: 169159 Error Type: Hardware . Selection: 120KV 40mA MA loop=1 (0=Open 1=Closed) Tolerance: Upper=42.0mA Lower=37.9mA Total samples: 53 . Samples Aver mA . Aver mA Above Tol Above Tol below Tol Below Tol ----------------------------------------------------------------- Anode 37.3mA 0 0.0mA -- -- Cath 40.1mA 14 45.8mA 18 35.8mA

Applies to

Models
LightSpeed
Product
LightSpeed 4.X - GRE See Long Description for detailed information - H2_P_M16 Product Name: LightSpeed 4.X with GRE Product Photographs GE HEALTHCARE Method of remote or software identification - See attachment below for a complete list of software commands and typical results 1. check_config 2 . swhwinfo “swhwinfo” will have the following switches: · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da List of Supported Console types: GOC3 (GRE) GOC4 (GRE) List of software the product can run: 07MW11.10 SP2.0, SP3.0, SP3.1 FAQ's Table weight limit - 180 kg (400 lbs) normal operation - 205 kg (450 lbs) maximum allowed with decreased accuracy Tube type - D3186T D3186T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Component
2154834 MA Board used on (CT/i,1.X-4.X) scanners See Long Description for more Part #: 2154834 Part Type: GP CONSUMABLE - RETURNABLE Part Weight: 1.81 LBR Repairable: No Returnable: Yes Hazardous Material: N Description: MA CONTROL BRD./CANCEL FRU: Yes Status: Orderable Comments: FLS - MA BOARD USED ON FAST RHAPSODE FMI#25238 UPGRADES THIS BD. TO A REV.1 ONE USE LIGHTSPEED ULTRA HQT WARNING!! MATERIAL MUST BE PURCHASED FROM MFGING DO NOT GO TO VENDOR AS IT MUST BE TESTED IN MFGING BEFORE SHIPPED TO FIELD VERY VERY HIGH DOA RATE. MS08992 GVR 7/31/00GELS
Area
CT