LightSpeed 7.x (VCT, VCT Select, Pro32)

Symptom

Cradle does not move on GT table or stuck at the home position. Table moves OK, but Cradle will not drive IN or OUT of gantry.

Error message

Error: 260134604 Cradle Motion Control task received invalid command.messageCode = 5120 current state = 3 See LD for more details Error: 260134604 Cradle Motion Control task received invalid command.messageCode = 5120 current state = 3 Fri May 5 09:38:39 2006 Error: 260134604 Host: tgp Process: tgp subsys File: gtcb cmc.cxx Line: 256 Fri May 5 09:38:39 2006 Host : Table Sub-System Ermes # : 260134604 Exception Class : Secondary Severity : Pri/Soft File : gtcb cmc.cxx Line# : 256 Function : No System Function Reported Scan Type : None/Unknown Scan: 928/2/0 Cradle Motion Control task received invalid command. messageCode = 5120 current state = 3

Error: 260134643 Cradle speed correction cannot cover such a large speed error See long description for full error Mon Mar 24 02:06:22 2008 Error: 260134643 Host: tgp Process: tgp subsys File: gtcb cmcmon actions const.cxx Line: 181 Mon Mar 24 02:06:22 2008 Host : Table Sub-System Ermes # : 260134643 Exception Class : Secondary Severity : Pri/Soft File : gtcb cmcmon actions const.cxx Line# : 181 Function : No System Function Reported Scan Type : None/Unknown Scan: 0/0/0 Cradle speed correction cannot cover such a large speed error. target sp

Applies to

Models
LightSpeed, VCT
Product
LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.