GE Healthcare · CTHiSpeed
CT System with Partial UPS will not turn on.
Symptom
CT System with Partial UPS (1.5 and 2 KVA units) will not turn on. UPS system has a battery fault. CT Systems with Partial UPS (1.5 and 2 KVA units) will not turn on.
Applies to
- Models
- HiSpeed
- Product
- HiSpeed YMS Series HiSpeed Series DXi, FXi, LXi, ZXI, and NXI Including Single / Twin detector and Glass / Metal Tubes. See Long Description for Details Subsystem/Components DXI (NP) FXI,LXI (NP+) ZXI (NP++ NXI (NP+ Twin NXI (NP++ Twin OC O2 running Unix or upgraded to Linux PC Gantry Alighnment Lights Halogen Laser Laser Laser Laser Mechanics Common Electronics firmware is different twin Det/Das Twin Det/DAS Table IMS no Yes Yes Yes Yes Generator Jedi Jedi NP++ Jedi Jedi NP++ Jedi Tube D3142T D3142T D3152T D3142T D3152T PDU Common Options List for V/R 5.5, 6, 7, 9, and 10 System 3D Power 440ma Max Image Disk 20000 Smart Prep Fast Scam 0.7 sec Performix 530 cooling Smart Recon Fast Scan 0.8 sec Asymmetric Scan SmartView Fast Scan 1.0 sec Cardiac gating DemtaScan Helical 30 Max Smart Addition Navigator Helical 60 Max Respiratory Gating Helical Plus Helical 120 Max Reformat Cpmmect {rp Raw Data 1000 max VolumeRendering2 ImageDosk Remote Tilt CT Colono Pioneer Mod Enhanced Cooling The following Options name changes Option (V5.5x,V6.0x,V7.x,V9.x,V10x) Option (V8.1x and V11.x) 3D >> Volume Analysis2 Navigator >> Navigator2,VolumeRendering2,VolumeAnalysis2 CtPerfusion >> CTPersusion2 Reformat >> Functool Options V8.1x and V11.x VolumeAnalysis2 Power 440ma ImageDisk 2000 Helical Plus Smart Prep Fast Scan 0.7 sec Performix 530 cooling Connect Pro Smart Recon Fast Scan 0.8 sec Asymmetric Scan ImageDisk SmartView Fast Scan 1.0 sec Cardiac Gating Pioneer MOD* DentaScan Helical 30 Smart Addition Power 200 ma max Navigator2/VolumeRendering2/ VolumeAnalysis Helical 60 Respiratory Gating Power 250 ma Max Power 300 ma Max Helical 120 Thickness 0.5mm CTColon Power 350 ma Max Raw data 1000 CtPerfusion2 AdvVesselAnalysis Remote Tilt Extended FOV Functool Enhance Cooling Performix Tube VolumeRendering2
- Component
- Uninterruptible Power Supply (UPS) (PowerWare 9125) with an Emergency Power Off (EPO) panel (Cat E4504AL,old cat numbers were E4504AJ and prior to that E4504AE) Partial UPS cat # of the Parital UPS is the following E4504AL (old cat numbers were E4504AJ and prior to that E4504AE) E4504AL consists of a Powerware 9125, 2000VA/1300W uninterruptible power supply system with Emergency Power Off Panel rated 20 amperes, 120 volt, 60 Hz, along with all of the necessary cables and instructions required for installation. DESIGNED FOR GEs YMS CT OPERATOR CONSOLE & OTHER ELECTONICS. Partial UPS cat # of the Parital UPS is the following E4504AL (old cat numbers were E4504AJ and prior to that E4504AE) E4504AL consists of a Powerware 9125, 2000VA/1300W uninterruptible power supply system with Emergency Power Off Panel rated 20 amperes, 120 volt, 60 Hz, along with all of the necessary cables and instructions required for installation. Powerware 9125 UPS Product Literature http://powerquality.eaton.com/Products-services/legacy/9125-info.asp Overview The E4504AL combines an online Uninterruptible Power Supply (UPS) with an Emergency Power Off (EPO) panel into an integrated system providing protection for the computer console and other selected electronics as well as the systems emergency shutdown. The Powerware 9125 model UPS supports the E4504AM. Standard Applications GE YMS CT operator console. Contact GE for application with other systems. Applications of UPS GE uses a Powerware UPS providing reliable, clean, constant Voltage for powering Diagnostic Imaging equipment. The use of Uninterruptible power enables the system computer to remain on line, eliminating computer software and data loss. The UPS eliminates power anomalies such as noise, transients, overvoltages and undervoltages, which could damage imaging system’s sensitive computer components. Utilizing a UPS improves system reliability, reduces service costs, and increases system up time. The UPS has been extensively tested and approved by GE Medical Systems for use with GE CT, Nuclear, and MR Systems.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required