GE Healthcare · CTLightSpeed2601000912601001115014026010009050234
LightSpeed 5.X (60kW)
Symptom
Scanner Hardware Stopped Scan. Scanner Hardware Stopped Scan
Error message
Error: 260100091 The Kxg Contactor Status Signal changed state unexpectedly. Contactor Status: Open. See Long Description for complete error Mon Sep 17 07:41:15 2007 Error: 260100091 Host: tgp Process: tgp_subsys File: scIsrService.c Line: 190 Mon Sep 17 07:41:15 2007 Host : Table Gantry Processor Ermes # : 260100091 Exception Class : Abort Severity : Primary File : scIsrService.c Line# : 190 Function : SYSTEM MONITORING : HVDC Monitor Scan Type : Helical Scan: 124/2/1 PDU Kxg Contactor Status. The Kxg Contactor Status Signal changed state unexpectedly. Contactor Status: Open. Error: 260100111, The PDU Kxg Contactor has NOT closed in the alloted time. See LD for complete error Wed May 10 14:42:41 2006 Error: 260100111 Host: tgp Process: tgp_subsys File: scHvdcMgr.c Line: 351 Wed May 10 14:42:41 2006 Host : Table Gantry Processor Ermes # : 260100111 Exception Class : Abort Severity : Primary File : scHvdcMgr.c Line# : 351 Function : SYSTEM MONITORING : HVDC Monitor Scan Type : Static Scan: 50140/1/1 The PDU Kxg Contactor has NOT closed in the alloted time. Timeout:2000 msec Contactor Status: Open. Error: 260100090 The Kss Contactor Status Signal changed state unexpectedly. Contact
Applies to
- Models
- LightSpeed
- Product
- LightSpeed 5.X (60kW) LightSpeed 5.X (60kW) ~ Use with MDAS or GDAS HP_P_G4 HP_P_G8 HP_P_G16 HP_P_M16 LightSpeed 5.X 60KW G-DAS16 with GRE Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 2351488 100A CONTACTOR Kxg in NGPDU See Long Description for Details. Part #: 2351488 Part Type: GP CONSUMABLES Part Weight: 3.44 LBR Repairable: No Returnable: No Hazardous Material: N Description: 100A CONTACTOR FRU: Yes Status: Orderable Comments: FLS - 100 A CONTACTOR. ADDED PER NGPDU RSPL FROM ASIA. MS20544 ON 1/2/03. Note: 100 Amp Kxg contactor located to the right of NGPDU fuses F1, F2, and F3 New contactor and Service Kit for NGPDU to replace the old Kxg contactor 2351488 upon failure when current stock is depleted . 5337228 is new Kxg contactor used in NGPDU in forward production( mid 2009) For IB site, Service Kit 5344524 is released to replace original Kxg contactor 2351488
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required