Symptom

Mouse Lock-up - Mouse Pointer is frozen - Pointer does not move. See Long Description The mouse pointer is still visible but will not move. When Telnet-ing to the system and the computer is still up and running. Type halt to bring the system down.

Error message

Error: USB disconnect, address 2,3,4,5,6 seen in /var/log/messages see Long Description for error example Error: USB disconnect, address 2,3,4,5,6 seen in /var/log/messages Dec 23 12:50:10 bay54 kernel: usb 3-1: USB disconnect, address 2 Dec 23 12:50:11 bay54 kernel: usb 3-1: new low speed USB device using uhci_hcd and address 4 Dec 23 12:50:11 bay54 kernel: usb 3-1: configuration #1 chosen from 1 choice Dec 23 12:50:11 bay54 kernel: input: Logitech Optical USB Mouse as /class/input/input5 Dec 23 12:50:11 bay54 kernel: input: USB HID v1.10 Mouse [Logitech Optical USB Mouse] on usb-0000:00:1d.0-1

Applies to

Models
Discovery, VCT
Product
Discovery CT750 HD V40_PS_HD64_G_GTL V40_PS_HD64_G_GTM Discovery HD CT750 Method of visual identification HD gantry: Gray top and Gray Side covers with HD Markings Console Type: GOC6 has black SCIM and tower face Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da List of softwares the product can run (Consult attached FCT Software Cross Reference): 08MW39.4 - M3 (see attachement for M3 available options) 09MW29.14 - M4 (HD Options = M3 plus Gemstone Spectral Imaging, Gemstone Spectral Review and volume Helical Shuttle ) Example: Of difference with options software [insite@ct01 ~]$ swokinstall -p Product Software Option Keys: Gemstone Spectral Imaging Permanent HelicalShuttle Permanent Xtream Recon Permanent FAQ's Table weight limit: 500 lbs Tube Type - D3702T Green D3701T Current production - M4 Refer to product data sheets or Technical reference Manual, English 5317222-1EN Revision : 2 or later Refer to Application Tips and Work-Arounds Direction 5311815-1EN Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.