GE Healthcare · CTBrightSpeed200900025
Patient Schedule fails to display some patients when updated.
Symptom
Patient Schedule fails to display some patients when updated. Patient schedule fails to display some patients when updated.
Error message
Error: 200900025 Parse Failed : Invalid Worklist received from remote HIS(xxxx)(xxxx) :-xxx Note in the error example above that the error is referring to dicom tag number 0010 2154 . The numbers shown in this location of an error message like this will have the leading zeroes stripped off on tags that have leading zeroes such as the example shown. Thu Sep 28 00:01:23 2006 Error: 200900025 Host: gect1 Process: WLServer File: WLapiSystem.c Line: 191 Function: Data Management : OC Processing Patient Worklist Manager error Source File: WLS_mfm.c, Line: 1465, Status: 23 Parse Failed : Invalid Worklist received from remote HIS (10)(2154) :-113 Tue Sep 13 18:13:04 2011 Error: 200900025 Host: LS16 Process: WLServer File: WLapiSystem.c Line: 191 Function: Data Management : OC Processing Patient Worklist Manager error. Source File: WLS_mfm.c, Line: 1471, Status: 23 Parse Failed : Invalid Worklist received from remote HIS(32)(1060) :-114
Applies to
- Models
- BrightSpeed
- Product
- BrightSpeed HPower, Delight, Velocity or MERI HPower HP_P_G4_G_HPT Excel HP_P_G8_G_HPT Edge HP_P_G16_G_HPT Elite HP_P_G16_G_GMV Elite HP_P_P16_G_GMV Elite HP_P_M16_G_HPT BrightSpeed Method of remote software hardware identification check_config swhwinfo List of Supported Console Types : HP_P_G16_ G _HPT Note: G could be GRE, AIO or TIO - check with: cat /usr/g/config/INFO | grep CONSOLETYPE GOC4 AIO TIO List of softwares the product can run: 08BW20.1 07MW11.10 08BW44.1 ( Delight ) 09HW30.4 ( Velocity ) 09BW35.11 ( MERI - Pancake DAS ) FAQ's 1. All BrightSpeed Power Systems use the Performix tube D3186T HP_P_G4_G_HPT (Excel - H-Power Table) HP_P_G8_G_HPT (Edge -H-Power Table ) HP_P_G16_G_HPT (Elite -H-Power Table ) HP_P_G16_G_GMV (Elite -Global Table Mid Value - modified GT1700 no IMS ) Note: G could be GRE, AIO or TIO (check with: cat /usr/g/config/INFO | grep CONSOLETYPE ) BrightSpeed Elite Power Systems will only be sold as Velocity System starting in 2Q/2010. Delight Elite Power being phased out 1Q/2010 BrightSpeed Power 4 & 8 slice systems have been discontinued due to restructuring of the product lineup. Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required