GE Healthcare · X-ray R&FAdvantxRevolution
Digital Rad Error 6D00 on Advantx-E console.
Symptom
Revolution XRd Gipeto Digial Rad Error 6D00 on Advantx-E console. No exposures are possible in Applications. .
Error message
Error 6D00 Acquisition Prep error reported from Digital Workstation See Long Description 6D00Example: Advantx Console6D00 Error Status Received in ADS PREP Reply From the ADS Error Log ,2003-11-04,12:22:21:000,ASC,06D00,ERROR STATUS RECEIVED IN ADS PREP REPLY,,,,AWS,,,1,, ,HWStatus=0001 User=0000 From the Advantx-E Error Description MESSAGES Console Error Message : Acquisition Prep error reported from Digital Workstation. Debug Mode Error Message: ERROR STATUS RECEIVED IN ADS PREP REPLY Debug Mode Numeric Fields: HW: 00H = O.K.01H = Client not available02H = IDC communication error04H = Medical Application error08H = ADS error10H = Sequence errorUSER: N/A MODULE ADS DESCRIPTION The ADS workstation reported an error condition in the Prep Status message sent to the ASC. RECOMMENDED ACTIONS 1. Try to Prep the system again.2. Verify the Medical Application is active on the ADS.3. Verify that a Patient Exam is active.4. Verify the Ethernet connection from the ADS to the Ethernet HUB.5. Verify the Ethernet connection from the IDC to the Ethernet HUB.6. Restart the Browser on the ADS workstation.7. Reboot the ADS workstation.8. Reboot the system.
Applies to
- Models
- Advantx, Revolution
- Product
- Advantx-E
- Software
- Gipeto Version 29.2 Gipeto version 28.4
- Component
- IDC – AWS – Transceivers – Fiber Cabling
- Area
- X-ray R&F
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray R&F issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray R&F issues
- ADx-E Advantx-E console displayed a 6C00 Error (Digital Imaging Subsystem error - Error status received in IDC Prep Reply) when the first exposure of detector bad pixel calibration was attempted; cali…
- Revolution XR/d After a Load From Cold, the AWS exhibits strange operation and the SUIF does not have any Positioner Configuration and Calibration selections due to the use of the incorrect Jumpstart…
- Revolution XRd2X Worklist query on "All Systems in this Modality" does not retrieve anything after FMI 10791A is completed due to the default query set to DX.
- Revolution XR/d error 4280 when trying to make exposure to table or wallstand detector
- Revolution XRd 2X The HP Workstation reboots itself.
- ADXE RFX/SFX Legacy popping noises during angulation SN 3715