GE Healthcare · CTLightSpeed
START button at the SCIM does not flash after confirming the scan
Symptom
START button at the SCIM does not flash after confirming the scan
Applies to
- Models
- LightSpeed
- Product
- LightSpeed RT4 WB O G4 G HPT WB O M4 G HPT LightSpeed RT4 with GRE and MDAS4 or GDAS4 gantry At GE Medical Systems, we’re pioneering exciting CT technology for Radiation Therapy planning. Introducing the newest addition to our LightSpeed® series – LightSpeed RT, the first multi-slice, wide-bore CT scanner with the largest field of view in the industry. With a generous 80 cm gantry opening, the LightSpeed RT bore is 10 cm larger than conventional scanners. This provides complete flexibility for patient positioning freedom – even for the most demanding oncology needs. And the 65 cm variable field of view delivers 15 additional centimeters of visual coverage, allowing clinicians to see a patient’s entire anatomy for precise radiation therapy planning. Position and precision Thin, multi-slice imaging is the extra bonus – enabling respiratory gating, providing precise target delineation and delivering higher resolution digitally reconstructed radiographs (DRRs) than ever before. All adding up to the ability for you to deliver what really matters most – better cancer care for your patients. Plus, the LightSpeed RT scanner is available with the Exact™ couch insert, enabling you to consistently replicate patient immobilization for treatment. With LightSpeed RT, the future of your Radiation Oncology department is wide open. Links to the Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 2275752 SCIM collector - english. See long description for details. Part #: 2275752 Part Type: GP CONSUMABLES Part Weight: -82269.18 LBR Repairable: No Returnable: No Hazardous Material: N Description: SCIM COLLECTOR - ENGLISH FRU: Yes Status: Orderable Comments: FLS - SCIM COLLECTOR ENGLISH MS26561 DSM SEE FE ASSIST NOTES: ***** A NEW SCIM WILL NOT FIX:(1) INTERCOM SOUND QUALITY: THERE WILL BE AN FMI TO FIX INTERCOM OUT WK 30, (2) STICKING KEYS: TRIM TEMPLATE TO FREE KEYS, DO NOT DISCOUNT - PER SHAKUN SHOOTING PROCEDURES IN SYSTEM SERVICE MANUAL***** KIT# B7800KE INCLUDES THIS PART VC = ADVANCED INPUT DEVICES COEUR D'ALENE, ID FLS - ***A NEW SCIM WILL NOT FIX: 1) INTERCOM SOUND QUALITY - THERE WILL BE A FMI TO FIX INTERCOM OUT WK30, 2) STICKING KEYS:TRIM TEMPLATETO FREE KEYS YOU MUST REVIEW TROUBLE SHOOTING PROCEDURES IN SYSTEM SERVICE MANUAL*** FE ASSIST: 6/27/02
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required