GE Healthcare · CTLightSpeed260118192
LightSpeed 5.X (60kW)
Symptom
Scanner Hardware Stopped Scan with open filament error in log. Scanner Hardware Stopped Scan with open filament error
Error message
Error: 260118192 (50-0211)Jedi detected open filament circuit. See Long description for full error Host: Jedi Ermes #: 260118192 Exception Class: Abort Severity: Primary File: gen_exec.c Line#: 2148 Function: No System Function Reported Scan Type: Helical Scan: 542/2/1 (50-0211) Jedi detected open filament circuit. Verify tube, HV cable, HV tank filament transformer, and Jedi interconnect cables are properly installed. RMS filament current measurement (every 0.5 msec) on heater board too high. Z6,Z7= 97h,0h
Applies to
- Models
- LightSpeed
- Product
- LightSpeed 5.X (60kW) LightSpeed 5.X (60kW) ~ Use with MDAS or GDAS HP_P_G4 HP_P_G8 HP_P_G16 HP_P_M16 LightSpeed 5.X 60KW G-DAS16 with GRE Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 5128609-8 (replaces 2201185-3 - P9230TP) - HV Cable Cathode 2.3M - Used on Jedi HP 60 generator See Long Description for Details 5128609-8 Cathode HV Cable (2.3 meters long. Used on LightSpeed HP60 and BrightSpeed Systems) Part #: 5128609-8 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: HV CABLE FRU: Yes Status: Orderable Comments: **FE ASSIST** 2300mm long HV cable from Cathode to HV tank Negative (212001261 May 4 2011) added per to NPI#019477 by sso#305010201 in Mar 28, 2010 Old FRU Compatible No Comments added per to ECR2109209 by sso#305024364 in Nov 2, 2010 Additional FRU Needed No Old FRU Scrapped No Old FRU Upgradable No Use on Hands Yes Use Demand History Yes Ultimate Prime 5128609-8 New FRU Backward Compatible Yes Old FRU Usable Yes Change Type Direct ECO Number ECR2109209 2201185-3 - P9230TP - HV Cable Cathode 2.3M - Used on Jedi HP 60 generator, Model # 2371333-2 Part #: 2201185-3 Part Type: GP CONSUMABLES Part Weight: 2.43 LBR Repairable: No Returnable: No Hazardous Material: N Description: P9230TP HV CABLE CATHODE 2.3M FRU: Yes Status: Orderable
- Area
- CT
Full cause & step-by-step resolution