Pular para o conteúdo principal
GE Healthcare · CTLightSpeed

LightSpeed 2.X (Plus, QX/i) - Octane

Symptom

Using press to talk button on scim does not allow talking to patient on intercom. See Long Description for more information. Using press to talk button on scim does not allow talking to patient on intercom The problem is , I can hear sound from patient to scan room but can not talk to patient due to talk switch on SCIM not response. When I pressed this switch ,I still hear the sound from gantry room at SCIM. Autovoice is OK.No problem

Applies to

Models
LightSpeed
Product
LightSpeed 2.X (Plus, QX/i) - Octane Always S-DAS 2.4.2_H2.4M5 LightSpeed 2.X (Plus, QX/i) - Octane (Pegasus or Rhapsode IG) - Always S-DAS Method of visual identification Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config List of Supported Console Types Octane with Pegasus Recon hardware. List of softwares the product can run 2.4.2_H2.4M5 FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3186T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 FEATURES/OPTIONS STD/OPTION Cat # Digital Laser Camera I/F B7700PD Smart Helical (s/w only) Standard B7530TK Fast Recon (s/w only) Option B7700JF BMD (requires B7710MP or MN) Option B7710MK Smart Prep Option B7530SP Smart Score ? ? 3D Analysis (Requires D3D) Option B7540TD Navigator (s/w only) Option B7540N DentaScan (s/w only) Option B7540SD Direct 3D (Requires B7710SA) Option B7810SS HIS/RIS Option (h/w and s/w) Option B7500PN Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Component
2275752 SCIM collector - english. See long description for details. Part #: 2275752 Part Type: GP CONSUMABLES Part Weight: -82269.18 LBR Repairable: No Returnable: No Hazardous Material: N Description: SCIM COLLECTOR - ENGLISH FRU: Yes Status: Orderable Comments: FLS - SCIM COLLECTOR ENGLISH MS26561 DSM SEE FE ASSIST NOTES: ***** A NEW SCIM WILL NOT FIX:(1) INTERCOM SOUND QUALITY: THERE WILL BE AN FMI TO FIX INTERCOM OUT WK 30, (2) STICKING KEYS: TRIM TEMPLATE TO FREE KEYS, DO NOT DISCOUNT - PER SHAKUN SHOOTING PROCEDURES IN SYSTEM SERVICE MANUAL***** KIT# B7800KE INCLUDES THIS PART VC = ADVANCED INPUT DEVICES COEUR D'ALENE, ID FLS - ***A NEW SCIM WILL NOT FIX: 1) INTERCOM SOUND QUALITY - THERE WILL BE A FMI TO FIX INTERCOM OUT WK30, 2) STICKING KEYS:TRIM TEMPLATETO FREE KEYS YOU MUST REVIEW TROUBLE SHOOTING PROCEDURES IN SYSTEM SERVICE MANUAL*** FE ASSIST: 6/27/02
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare CT issues