GE Healthcare · CTLightSpeed260100028
LightSpeed 5.X (80/100kW)
Symptom
Scanner Hardware Stopped Scan. Scanner Hardware Stopped Scan
Error message
Error: 260100028 Scan Control timed out waiting for the Ready For Views message from the SRU. See LD Fri Jan 7 09:25:36 2005 Error: 260100028 Host: tgp Process: tgp_subsys File: scTrigSeqActions.c Line: 1539 Fri Jan 7 09:25:35 2005 Host : Table Gantry Processor Ermes # : 260100028 Exception Class : Abort Severity : Primary File : scTrigSeqActions.c Line# : 1539 Function : DATA ACQUISITION : Scan Data Acquisition Scan Type : Scout Scan: 470/1/2 Scan Control timed out waiting for the Ready For Views message from the SRU. This message is sent from the SRU once offset collection has comple ted. Possible causes: trigger failure, DIP failed to receive data, message lost, software error.
Applies to
- Models
- LightSpeed
- Product
- LightSpeed 5.X (80/100kW) LightSpeed 5.X (80/100kW) ~ Use with both MDAS and GDAS ~ GRE Console HP_H_G16 HP_H_M16 HP_O_M16 LightSpeed 5.X (100kW) GDAS16 with GRE Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 2333314 cable for the Collimator J1 to to Right Das backplane J30 This cable carries the CCB DCB ORP can bus. This cable maybe damaged during a tube change on H-power systems because the close proximity on the collimator CAN bus cable. The 233314 RCIB BUS cable carries the CCB DCB ORP CAN Communications, but this cable 2333314 also carries Das triggers. The Missing Das trigger was what was causing the issue. By wiggling the Collimator cable 2333314 at J1 could get the system to start working again 2333314 cable for the Collimator J1 to to Right Das backplane J30 part number is 2333314. This cable carries the CCB DCB ORP can bus. This cable maybe damaged during a tube change on H-power systems because the close proximity on the collimator CAN bus cable. The 233314 RCIB BUS cable carries the CCB DCB ORP CAN Communications, but this cable 2333314 also carries Das triggers. The Missing Das trigger was what was causing the issue. By wiggling the Collimator cable 2333314 at J1 could get the system to start working again.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required