Lightspeed 1.X - Octane
Symptom
Intermittent Scan Aborts at beginning of scan, Wrong angle Scouts (0 degree image looks more like 90 degree), All laser lights do not light. See LD for more details Intermittent Scan Aborts at beginning of scan, Wrong angle Scouts (0 degree image looks more like 90 degree), All laser lights do not light. 3 symptoms were seen 1 – Axial scans intermittently Abort at the beginning of the scan of the scan. 2 – Scouts scans intermittently Abort at the beginning of the scan. In addition sometimes if a 0 degree Scout is prescribed, when the picture is reconstructed it doesn’t look like it was taken at 0 degrees. It looks more like a Scout image taken at 90 degrees. 3- The laser lights intermittently do not all light. Specifically the external lights were mentioned as not being on. (or came on but because the gantry was not rotating to the correct location. The lights did not shine through the laser light cutouts in the gantry)
Error message
Error: 183911 Axial HOME value TIMEOUT Fault See Long Description for complete error Tue Nov 15 07:01:52 2005 Error: 183911 Suite: CT27 Host: STC Process: Axial File: ax_error.c Method: No Method Line: 1114 Function: AXIAL CONTROL : Axial Servo Control Loop Scan: 65001/11/0 Type: None/Unknown Exception Level: Pri/Most Severe Time: 07:01:50:045 Log Series: 1014 Axial HOME value TIMEOUT Fault. HW/SW Error: Retry Rx to verify probable gantry hardware problem.
Applies to
- Product
- Lightspeed 1.X - Octane 10.5_2.8.2I_H1.3M4 10.4.1_2.8.2I_H1.3M4 - obsolete Lightspeed 1.X - Octane Method of visual identification Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config showprods|grep Apps note: if check_config does not work then the software is not up to date with all FMI's. Check FMI history and verify that all patches have been loaded since last software reload. Ref FMI 25269 List of Supported Console Types Octane with Pegasus Recon hardware. may have an 02 SBC - Run df -k to see if the sbc is partitioned. List of softwares the product can run 10.5_2.8.2I_H1.3M4 10.4.1_2.8.2I_H1.3M4 - obsolete FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3176T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required