Pular para o conteúdo principal
GE Healthcare · CTBrightSpeed2600078485009226000785019933

Scanning not allowed detector temperature too high

Symptom

Scanning not allowed detector temperature too high

Error message

Error: 260007848 DHCB Sensor and/or Control Abort error See long description for full error Host: DAS Process: DCB Firmware File: detmgr.c Line: 1090 Function: DATA ACQUISITION : Scan Data Acquisition Scan: 50092/1/1 Type: Axial Exception Level: Sec/Soft Time: 09:22:54:900 Log Series: 43 DHCB has issued an abort condition - DHCB Error is as follows: DHCB Sensor and/or Control Abort error

Error: 260007850 DHCB has CLEARED the following error: DHCB Sensor and/or Control Abort error. Error: 260007850 Host: DAS Process: DCB Firmware File: detmgr.c Line: 1125 Function: DATA ACQUISITION : Scan Data Acquisition Scan: 19933/2/0 Type: None/Unknown Exception Level: Pri/Soft Time: 16:50:48:060 Log Series: 505 DHCB has CLEARED the following error: DHCB Sensor and/or Control Ab Error: 260007850 Host: DAS Process: DCB Firmware File: detmgr.c Line: 1125 Function: DATA ACQUISITION : Scan Data Acquisition Scan: 19933/2/0 Type: None/Unknown Exception Level: Pri/Soft Time: 16:50:48:060 Log Series: 505 DHCB has CLEARED the following error: DHCB Sensor and/or Control Abort error.

Applies to

Models
BrightSpeed
Product
BrightSpeed HPower, Delight, Velocity or MERI HPower HP_P_G4_G_HPT Excel HP_P_G8_G_HPT Edge HP_P_G16_G_HPT Elite HP_P_G16_G_GMV Elite HP_P_P16_G_GMV Elite HP_P_M16_G_HPT BrightSpeed Method of remote software hardware identification check_config swhwinfo List of Supported Console Types : HP_P_G16_ G _HPT Note: G could be GRE, AIO or TIO - check with: cat /usr/g/config/INFO | grep CONSOLETYPE GOC4 AIO TIO List of softwares the product can run: 08BW20.1 07MW11.10 08BW44.1 ( Delight ) 09HW30.4 ( Velocity ) 09BW35.11 ( MERI - Pancake DAS ) FAQ's 1. All BrightSpeed Power Systems use the Performix tube D3186T HP_P_G4_G_HPT (Excel - H-Power Table) HP_P_G8_G_HPT (Edge -H-Power Table ) HP_P_G16_G_HPT (Elite -H-Power Table ) HP_P_G16_G_GMV (Elite -Global Table Mid Value - modified GT1700 no IMS ) Note: G could be GRE, AIO or TIO (check with: cat /usr/g/config/INFO | grep CONSOLETYPE ) BrightSpeed Elite Power Systems will only be sold as Velocity System starting in 2Q/2010. Delight Elite Power being phased out 1Q/2010 BrightSpeed Power 4 & 8 slice systems have been discontinued due to restructuring of the product lineup. Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Component
2147197 Thermistor Probe See Long Description for Details. 2147197 Thermistor Probe Part #: 2147197 Part Type: GP CONSUMABLES Part Weight: 0.00 KGM Repairable: No Returnable: No Hazardous Material: N Description: THERMISTOR PROBE FRU: Yes Status: Orderable Comments: FLS - THERMISTOR PROBE / TEMPERATURESENSOR CT - 0970
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required