LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
Oil found coming out of Gantry Base. IMPORTANT: See Long Description Oil found coming out of Gantry Base. Contact Tubes for Major Oil Leak Recommendations Ryan August 414 - 745 - 8127 or Tom Hurdis 262 - 510 - 5782 or John Breunissen 414 - 202 - 9485 Encourage Warm-ups NOT use of lower mA Verbiage in the Operator Console (OC) messaging has changed from “ should ” to “ must ” as shown below. Additional information in customer documentation advises “ Tube Warm-Up takes 72 seconds to complete. Failure to perform Tube Warm-Up when requested may cause serious equipment damage and decrease tube life. ” Failure to perform the warm-up would be classified as a “violation of GE Healthcare’s recommendations or instructions on use” and is disclaimed in the Tube Warranty. (See “Limitations” section excerpted from the Tubes Warranty document and printed below.
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Component
- 5124371 VCT Heat Exchanger with Dielectric oil flushed and filled. See Long Description for Details. Part #: 5124371 Part Type: GP CONSUMABLES Part Weight: 180.78 LBR Repairable: No Returnable: No Hazardous Material: N Description: Performix PRO VCT Heat Exchanger with Dielectric oil flushed and filled. FRU: Yes Status: Orderable 5105346-3 (replaces 5105346-2 and 5105346) RoHS Compliant Performix PRO 100 Smart Pump - VCT or HD See LD for details. 5105346-3 RoHS Compliant Performix PRO 100 Smart Pump - VCT or HD Part #: 5105346-3 Part Type: GP TUBES Part Weight: 0.00 LBR Repairable: No Returnable: Yes Hazardous Material: N Description: RoHS Compliant Performix PRO 100 Smart Pump - VCT or HD FRU: Yes Status: Orderable Old FRU Compatible Yes Comments Rohs- Old part can be used on new systems. Flag to yes mar 18 2011 212008958 Per ECR 2100751, 212008898, 4 Jan 2011. Additional FRU Needed No Old FRU Scrapped No Old FRU Upgradable No Use on Hands Yes Use Demand History Yes Ultimate Prime 5105346-3 New FRU Backward Compatible Yes Old FRU Usable Yes Change Type Indirect ECO Number ECR2100751 Part #: 5105346-2 VCT PUMP / ADAPTER / HOSE ASM. Part Type: GP CONSUMABLE - RETURNABLE Part Weight: 0.00 LBR Repairable: No Returnable: Yes Hazardous Material: N Description: Performix PRO 100 VCT Pump, Hose Asm. and Mounting Bracket Assembly, With furnished mounting hardware Pump Support Bracket and U-bolt Assembly and Flush and Filled with Dielectric Oil. FRU: Yes Status: Orderable Comments: This part is replacement for 5105346. Do NOT use 5105346 to replace a 5105346-2, ms13452 060131
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required