Pular para o conteúdo principal
GE Healthcare · CTLightSpeedVCT26013317226000102350011260003117260133176260133169

LightSpeed 7.x (VCT, VCT Select, Pro32)

Symptom

Scan aborts. Scans abort

Error message

Error: 260133172 The Aperture failed to move to the requested position See Long Description for complete error Thu Feb 23 08:15:31 2006 Error: 260133172 orp orp_subsys aperture_move.cxx 231 Thu Feb 23 08:15:31 2006 Host : Collimator Ermes # : 260133172 Exception Class : Abort Severity : Secondary File : aperture_move.cxx Line# : 231 Function : No System Function Reported Scan Type : None/Unknown Scan: 1352/1/0 The Aperture failed to move to the requested position. EN 399

Error: 260001023 The CCB has notified the system of an error condition Fri May 11 06:44:04 2007 Error: 260001023 Host: OBC Process: HOP File: hop_erlog.c Line: 374 Function: No System Function Reported Scan: 50011/1/0 Type: None/Unknown Exception Level: Pri/Most Severe Time: 06:44:05:145 Log Series: 42 The CCB has notified the system of an error condition which prevents scanning . See log for further information: Error message code: 260003117 Notification level: 5 Sequence number: 4

Error: 260133176 Did not detect an encoder index pulse when homing CAM A / B. See LD for more details Did not detect an encoder index pulse when homing CAM A / B. Fri Jun 9 08:41:23 2006 Error: 260133176 Host: orp Process: orp_subsys 

Applies to

Models
LightSpeed, VCT
Product
LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
Component
2404178 MDRIVE 23 MOTOR See long description for deatils Part #: 2404178 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: MDRIVE 23 MOTOR FRU: Yes Status: Orderable Comments: Set as Critical Part for Product CT_VCT, ms04278, 05Oct28 analyist Added per VCT RSPL EMC2 compliance... MS8336 11/29/2004
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare CT issues