GE Healthcare · CTLightSpeedVCT260107204
LightSpeed RT with GRE and MDAS4 gantry
Symptom
The positioning lights will not come on when the Patient was being positioned for a scan The laser lights will not come on when the Patient was being positioned for a scan
Error message
Error: 260107204 Axial Motor Control (AMC) logic could not configure the AXIAL drive via the CAN network during configuration. Reset scan hardware to retry. See Long Description for full error Wed Apr 7 21:18:13 2004 Error: 260107204 Host: tgp Process: tgp_subsys File: amc_mgr.c Line: 230 Wed Apr 7 21:18:13 2004 Host : Table Gantry Processor Ermes # : 260107204 Exception Class : Abort Severity : Secondary File : amc_mgr.c Line# : 230 Function : AXIAL CONTROL : Axial Communications Scan Type : None/Unknown Scan: 0/0/0 Axial Motor Control (AMC) logic could not configure the AXIAL drive via the CAN network during configuration. Reset scan hardware to retry.
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed RT4 WB O G4 G HPT WB O M4 G HPT LightSpeed RT4 with GRE and MDAS4 or GDAS4 gantry At GE Medical Systems, we’re pioneering exciting CT technology for Radiation Therapy planning. Introducing the newest addition to our LightSpeed® series – LightSpeed RT, the first multi-slice, wide-bore CT scanner with the largest field of view in the industry. With a generous 80 cm gantry opening, the LightSpeed RT bore is 10 cm larger than conventional scanners. This provides complete flexibility for patient positioning freedom – even for the most demanding oncology needs. And the 65 cm variable field of view delivers 15 additional centimeters of visual coverage, allowing clinicians to see a patient’s entire anatomy for precise radiation therapy planning. Position and precision Thin, multi-slice imaging is the extra bonus – enabling respiratory gating, providing precise target delineation and delivering higher resolution digitally reconstructed radiographs (DRRs) than ever before. All adding up to the ability for you to deliver what really matters most – better cancer care for your patients. Plus, the LightSpeed RT scanner is available with the Exact™ couch insert, enabling you to consistently replicate patient immobilization for treatment. With LightSpeed RT, the future of your Radiation Oncology department is wide open. Links to the Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 46-170021P11 7.0A 250V SLO-BLO FUSE used in Hpower Axail Dynamic Brake Module 2357524 46-170021P11 7.0A 250V SLO-BLO FUSE used in Hpower Axail Dynamic Brake Module 2357524 46-170021P11 7.0A 250V SLO-BLO FUSE used in Hpower Axail Dynamic Brake Module 2357524. see attachment 1 and 2
- Area
- CT