GE Healthcare · CT18390814756399903984439453
Lightspeed 1.X - Octane
Symptom
Scanner Hardware Stopped Scan message when an axial or helical scan is attempted at speeds of .8 or 1 second See long description Scanner Hardware Stopped Scan message appears to operator whenever an axial or helical scan is attempted at 0.8 or 1.0 second scan speed with error 183908 Axial velocity ACCEL tracking fault posted in the gesyslog. Slower scan speed scans above 1.0 sec would still work ok. It was also noted that the gantry axial motor current stats were logging higher values than in previous days.
Error message
Error: 183908 Axial velocity ACCEL tracking fault See the Long Description for the full error code Mon Aug 27 09:12:45 2007 Error: 183908 Host: STC Process: Axial File: ax_error.c Line: 1114 Function: AXIAL CONTROL : Axial Servo Control Loop Scan: 14756/2/1 Type: Helical Exception Level: Pri/Most Severe Time: 09:12:45:860 Log Series: 363 Axial velocity ACCEL tracking fault. current: commanded = 39990 mA current: D/A measured = 39844 mA PDU measured = 39453 mA (HW/SW Error: Retry Rx to verify probable Axial Driver or. Axial Encoder hardware problem.)
Applies to
- Product
- Lightspeed 1.X - Octane 10.5_2.8.2I_H1.3M4 10.4.1_2.8.2I_H1.3M4 - obsolete Lightspeed 1.X - Octane Method of visual identification Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config showprods|grep Apps note: if check_config does not work then the software is not up to date with all FMI's. Check FMI history and verify that all patches have been loaded since last software reload. Ref FMI 25269 List of Supported Console Types Octane with Pegasus Recon hardware. may have an 02 SBC - Run df -k to see if the sbc is partitioned. List of softwares the product can run 10.5_2.8.2I_H1.3M4 10.4.1_2.8.2I_H1.3M4 - obsolete FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3176T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 2102012 Gantry axial motor brush and cap kit for Lightspeed 1x, CTi, HSA, HLA, and 9800 CT systems. See Long Description for details Part #: 2102012 Part Type: GP CONSUMABLES Part Weight: 0.45 LBR Repairable: No Returnable: No Hazardous Material: N Description: FOR 9800 HLA and HSA GANTRY AXIAL MTR FRU: Yes Status: Orderable Comments: FLS - MOTOR BRUSH & BRUSH CAPS KIT. PEERLESS-WINSMITH REPLACED AS SUPPLIER BY B.D.I. 8-31-01 PERLISA GILLIAN. MS7093 KIT CONTAINS 24 PIECE PARTS, CONSISTING OF: 46-194465P22 VN#819-23-0711-0 (8 PIECES PER KIT) FRU N 46-194465P23 VN#820-07-0200-0 (8 PIECES PER KIT) 46-194465P27 VN#820-07-1300-0 (8 PIECES PER KIT) This kit includes 8 brushes and caps for gantry axial motors used in Lightspeed 1x, CTi, and HSA CT systems as well as 8 brushes and caps for gantry axial motors used in HLA and 9800 CT systems.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required