GE Healthcare · CTLightSpeed
LightSpeed 4.X - GOC2
Symptom
Customer reports various problems with the mouse. Any of the problems below: Mouse moves in one direction, but not the other. Mouse movement is erratic or intermittent. Mouse or the cable is physically damage. Etc. etc.
Applies to
- Models
- LightSpeed
- Product
- LightSpeed 4.X - GOC2 405L.8_H4.2M4 LightSpeed 4.X with GOC2 and MDAS 16 Gantry H4 Gantry Model # 2339985 and Global Operator Console 2 Model #'s 2366438 and 2366438-2(Hino) with HP8000 CPU (or newer) and Pegasus Recon ICE Box Product: LightSpeed16 405L.8_H4.2M4 CPU: GenuineIntel Intel(R) Xeon(TM) CPU 2.66GHz 4 2657 MHz i686 Processors Main memory size: 2048 Mbytes [root@presbyct2]# sg_map -i /dev/sg0 /dev/sda SEAGATE ST336753LW HPS2 /dev/sg1 /dev/sdb SEAGATE ST373453LW HPS1 /dev/sg2 /dev/sdc SONY SMO-F551-SD 1.05 /dev/sg3 /dev/scd0 MATSHITA DVD-RAM SW-9574S AZX8 /dev/sg4 /dev/scd1 HL-DT-ST DVD-ROM GDR8163B 0B15 [root@presbyct2]# df -h Filesystem Size Used Avail Use% Mounted on /dev/sda2 4.0G 1.7G 2.3G 41% / /dev/sda1 27M 12M 14M 44% /boot none 1008M 0 1007M 0% /dev/shm /dev/sda6 14G 3.5G 10G 25% /usr/g /dev/sda7 9.8G 753M 9.0G 8% /usr/g/sdc_image_pool /dev/sdb1 68G 28G 40G 41% /usr/g/sdc_image_pool2 Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 2368697-2 LINUX 3 BUTTON PS2 MOUSE See LD for details Part #: 2368697-2 Part Type: GP CONSUMABLES Part Weight: 0.22 LBR Repairable: No Returnable: No Hazardous Material: N Description: LINUX 3 BUTTON PS2 MOUSE FRU: Yes Status: Orderable Comments: FLS - LINUX DDR WORKSTATION 3 BUTTON PS2 MOUSE . THIS P/N REPLACES P/N 2330676-2 FOR THE GOC2-LINUX CONSOLE, PER PCN 220795. MS20544 ON 2/19/03. DO NOT!!!! CHANGE TO 2368697 THIS IS THE WHOLE COMPUTER! IN CASE YOU MAY NEED IT, YOU CAN PROCURE INSTEAD 2348405-2. (HP P/N Y1755A). THIS HAS BEENIDENTIFIED TO BE THE SAME AS P/N 2368697-2 (HP P/N A28314).(THE DIFFERENT HP P/NS ARE DUETO INTERNAL SUPPLY CHAIN INTEGRATION BETWEEN HP AND COMPAQ).MS20544 ON 3/11/03. PART PLACED ON CONSUMABLE COLLECTIO PER REQUEST OF CHAD VANDE HEI MS13452 030519 ALSO USED ON EXCITE II FROM MR, PER RSPL. MS20544 6/17/03.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required