GE Healthcare · CTLightSpeed200108011230015037200108010
LightSpeed 4.X - GOC2
Symptom
Fastcal scan aborts. Problem finding a calibration vector or calibration file.
Error message
Error: 200108011 The following calibration vector is not valid: See Long Description for complete error Mon Jun 20 07:06:46 2005 Error: 200108011 Host: ctxm Process: scanRx File: CalStatusInfo.cxx Line: 554 Function: Data Acquisition : OC Processing The following calibration vector is not valid: kV:120 sfov:SFOV_LARGE collimation:0 spotsize:LARGE_SPOT. Error:230015037 /usr/g/cal_db/kv120/large_sfov/1x125/large_spot/dasgain8/cal.1.acal has size: 0 See Long Description for complete error Mon Jun 20 07:06:45 2005 Error: 230015037 Host: ctxm Process: accs File: cal_db_utils.c Line: 1078 /usr/g/cal_db/kv120/large_sfov/1x125/large_spot/dasgain8/cal.1.acal has size: 0 Error: 200108010 This system has not been fully calibrated for XXX kV. You will not be able to scan at XXX kV until the system has been calibrated for this kV. See Long Description for complete error Mon Jun 20 07:06:46 2005 Error: 200108010 Host: ctxm Process: scanRx File: SIRx.cxx Line: 2380 Function: Data Acquisition : OC Processing This system has not been fully calibrated for 120 kV. You will not be able to scan at 120 kV until the system has been calibrated for this kV.
Applies to
- Models
- LightSpeed
- Product
- LightSpeed 4.X - GOC2 405L.8_H4.2M4 LightSpeed 4.X with GOC2 and MDAS 16 Gantry H4 Gantry Model # 2339985 and Global Operator Console 2 Model #'s 2366438 and 2366438-2(Hino) with HP8000 CPU (or newer) and Pegasus Recon ICE Box Product: LightSpeed16 405L.8_H4.2M4 CPU: GenuineIntel Intel(R) Xeon(TM) CPU 2.66GHz 4 2657 MHz i686 Processors Main memory size: 2048 Mbytes [root@presbyct2]# sg_map -i /dev/sg0 /dev/sda SEAGATE ST336753LW HPS2 /dev/sg1 /dev/sdb SEAGATE ST373453LW HPS1 /dev/sg2 /dev/sdc SONY SMO-F551-SD 1.05 /dev/sg3 /dev/scd0 MATSHITA DVD-RAM SW-9574S AZX8 /dev/sg4 /dev/scd1 HL-DT-ST DVD-ROM GDR8163B 0B15 [root@presbyct2]# df -h Filesystem Size Used Avail Use% Mounted on /dev/sda2 4.0G 1.7G 2.3G 41% / /dev/sda1 27M 12M 14M 44% /boot none 1008M 0 1007M 0% /dev/shm /dev/sda6 14G 3.5G 10G 25% /usr/g /dev/sda7 9.8G 753M 9.0G 8% /usr/g/sdc_image_pool /dev/sdb1 68G 28G 40G 41% /usr/g/sdc_image_pool2 Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required