Infinia Failure to Store Scan Data: Unable to install scan to database, SDB Error 4010
Infinia Failure to Store Scan Data
Symptom
Infinia Failure to Store Scan Data: Unable to install scan to database, SDB Error 4010
Error message
SDB_ERROR_IMAGE_INSTALLED,4010,ERROR SDB_ERROR_IMAGE_INSTALLED,4010,ERROR SDB_ERROR_IMAGE_INSTALLED,4010,ERROR 20:08:26 WARNING = Warning in PEFApp in Class Message.java:132 - DEVELOPMENT_ERROR_MESSAGE=Unable to install file d:\tacqdb/images/1.2.840.113619.2.170.1.2.0.26062008010548000.12310.dcm to the DB USER_ERROR_MESSAGE=Unable to install last Scan to database (file d:\tacqdb/images/1.2.840.113619.2.170.1.2.0.26062008010548000.12310.dcm) USER_FIX=Please restart the Application. After restart the last scan data could be found in the Data Management. Auto Send was not applied for this Scan. CODE=(SDB_ERROR_IMAGE_INSTALLED,4010,ERROR) SOURCE=com.ge.med.fi.tacq.hwifc.VG.SDB@13015e8 TIME_CREATED=Wed Jun 25 20:08:26 CDT 2008 USER_ERROR_MESSAGE=Unable to install last Scan to database USER_ERROR_MESSAGE = Unable to install last Scan to database 20:08:26 WARNING = Warning in PEFApp in Class Message.java:132 - DEVELOPMENT_ERROR_MESSAGE=Unable to install file d:\tacqdb/images/1.2.840.113619.2.170.1.2.0.26062008010548000.12310.dcm to the DB USER_ERROR_MESSAGE=Unable to install last Scan to database (file d:\tacqdb/images/1.2.840.113619.2.170.1.2.0.26062008010548000.12310.dcm) USER_FIX=Plea
Applies to
- Models
- Infinia
- Product
- Infinia I Infinia I Acquisition System Infinia II Infinia II Acquisition System Infinia HE4 Infinia II Hawkeye 4 & Infinia II GP (Infinia running Windows XP software)
- Software
- Infinia All Infinia All. Including Infina 1 and Infinia II. Infinia All. Including Infina 1 and Infinia II.
- Component
- *DICOM DICOM DICOM
- Area
- Nuclear Medicine
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare Nuclear Medicine issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare Nuclear Medicine issues
- Service Note 43783_1 Feb/08 Infinia/Ventri/Xeleris 1.1 & 2
- After software upgrade FMI40786, the Infinia application does not automatically start on boot up
- I need the product data sheet on catalog E4500AK x-ray in use warning light interface control panel for Infinia
- Infinia Does not recognize collimator is mounted to detector, not reading collimator ID correctly.
- Where do I obtain the Non-Linear Correction tables for a VG/Infinia Hawkeye system if can't find the CD that came with the DAS assembly?
- Hawkeye CT scan Ring (Circular) artifacts in X-ray images appearing in the same radius in all of the images.