GE Healthcare · CTLightSpeedVCT260118314244643

LightSpeed 7.x (VCT, VCT Select, Pro32)

Symptom

Warning pop-up appears on screen with Tube identity advisory. See Long Description for complete text of message. ! Attention An unrecognized X-Ray tube has been installed on the system. - GE Medical Systems cannot assure that the system performance will conform to specifications. - Advisory messages will be posted to the operator about an unrecognized tube during tube warm-up, during Fast Calibration, and in the dose report.

Error message

Error: 260118314 Could not verify tube ID against target configuration Status code: -3 When the system can not identify the tube the system will post a Pop-up window on every boot up, but will not stop the customer from scanning. Error 260118314 5 orp orp_subsys gen_exec.c 3695 No System Function Reported Soft Severity : Pri/Soft None/Unknown Scan: 0/0/0 Could not verify tube ID against target configuration Status code: -3

Error: 244643 Tube identity advisory: An unrecognized X-Ray tube has been installed on the system. See Long Description for complete error Thu Dec 21 15:35:37 2006 Error: 244643 Host: nsuhct2 Process: fwmgr File: tubeApprovalPopupMgr.cxx Line: 326 Tube identity advisory: An unrecognized X-Ray tube has been installed on the system. GE Medical Systems cannot assure that the system performance will conform to specifications.

Applies to

Models
LightSpeed, VCT
Product
LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare CT issues