GE Healthcare · CTLightSpeedVCT290012000260118213260118214290012001
LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
Reconstruction stopping intermittently while scanning with view correction errors
Error message
Error: 290012000 View corrections were applied in view # The errror 290012000 "View corrections were applied in view number" message indicate the Image Generator or recon software detected a corrupt view and has applied view corrections to image. This Error alone does not indicate a problem. See service note SN05102815a. Wed Feb 13 13:46:25 2008 Error: 290012000 Host: ig3 Process: image_generation File: MissedView.cpp Line: 129 View corrections were applied in view 5400. exam/series/scan = 345/2/1 From SN05102815a Error code 290012000 is a status notification that Recon has made a correction to maintain image quality. This error is transparent to the Customer and has no effect on system performance. This condition is generated when the IG reads in the scan data and checks the KV signal for each view. If the KV signal drops below a certain threshold, a correction is made by design. The low KV signal can be defined as a "High Voltage Disturbance". Do not assume the tube is the source of the problem. A healthy tube will typically generate 2000 to 3000 of these events during its normal life. Other potential sources for high voltage disturbances are the Jedi Generator, HV Tank, and cabl
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Component
- 5130200 VCT DCB PWA See long description for details Part #: 5130200 Part Type: GP CONSUMABLE - RETURNABLE Part Weight: 0.00 LBR Repairable: No Returnable: Yes Hazardous Material: N Description: VCT DCB PWA FRU: Yes Status: Orderable Parts Offered as: Current: 5130200 Harvested: Not Available Exchange: Not Available Comments: Added per VCT RSPL, ms13452
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required