Pular para o conteúdo principal
GE Healthcare · CT

Lightspeed 1.X Octane

Symptom

Console locked, no mouse movement.

Error message

/var/adm/SYSLOG ALERT: /hw/node/xtalk/15/pci/4 only one keyboard allowed; only one mouse allowed See long description for full error Apr 26 12:42:31 1A:dsmcgect01rd unix: ALERT: /hw/node/xtalk/15/pci/4 only one keyboard allowed Apr 26 12:44:23 1A:dsmcgect01rd unix: ALERT: /hw/node/xtalk/15/pci/4 only one mouse allowed

/var/adm/SYSLOG WARNING! Couldn't find core pointer device "mouse"

Applies to

Product
Lightspeed 1.X - Octane 10.5_2.8.2I_H1.3M4 10.4.1_2.8.2I_H1.3M4 - obsolete Lightspeed 1.X - Octane Method of visual identification Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config showprods|grep Apps note: if check_config does not work then the software is not up to date with all FMI's. Check FMI history and verify that all patches have been loaded since last software reload. Ref FMI 25269 List of Supported Console Types Octane with Pegasus Recon hardware. may have an 02 SBC - Run df -k to see if the sbc is partitioned. List of softwares the product can run 10.5_2.8.2I_H1.3M4 10.4.1_2.8.2I_H1.3M4 - obsolete FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3176T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Component
2368697-2 LINUX 3 BUTTON PS2 MOUSE See LD for details Part #: 2368697-2 Part Type: GP CONSUMABLES Part Weight: 0.22 LBR Repairable: No Returnable: No Hazardous Material: N Description: LINUX 3 BUTTON PS2 MOUSE FRU: Yes Status: Orderable Comments: FLS - LINUX DDR WORKSTATION 3 BUTTON PS2 MOUSE . THIS P/N REPLACES P/N 2330676-2 FOR THE GOC2-LINUX CONSOLE, PER PCN 220795. MS20544 ON 2/19/03. DO NOT!!!! CHANGE TO 2368697 THIS IS THE WHOLE COMPUTER! IN CASE YOU MAY NEED IT, YOU CAN PROCURE INSTEAD 2348405-2. (HP P/N Y1755A). THIS HAS BEENIDENTIFIED TO BE THE SAME AS P/N 2368697-2 (HP P/N A28314).(THE DIFFERENT HP P/NS ARE DUETO INTERNAL SUPPLY CHAIN INTEGRATION BETWEEN HP AND COMPAQ).MS20544 ON 3/11/03. PART PLACED ON CONSUMABLE COLLECTIO PER REQUEST OF CHAD VANDE HEI MS13452 030519 ALSO USED ON EXCITE II FROM MR, PER RSPL. MS20544 6/17/03.
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required