GE Healthcare · CTLightSpeedVCT260100119245190260100118
LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
Scanner Hardware Stopped Scan. Scanner Hardware Stopped Scan
Error message
Error: 260100119 Gantry Service Switch is Enabled. see long description Wed Jul 23 19:35:09 2008 Error: 260100119 Host: tgp Process: tgp_subsys File: scGantryInMail.c Line: 1034 Wed Jul 23 19:35:07 2008 Host : Table Gantry Processor Ermes # : 260100119 Exception Class : Secondary Severity : Sec/Soft File : scGantryInMail.c Line# : 1034 Function : SYSTEM MONITORING : HVDC Monitor Scan Type : None/Unknown Scan: 0/0/0 Gantry Service Switch is Enabled. Tue Apr 28 12:38:07 2009 Error: 260100119 Host: tgp Process: tgp_subsys File: scGantryInMail.c Line: 1206 Tue Apr 28 12:38:06 2009 Host : Table Gantry Processor Ermes # : 260100119 Exception Class : Secondary Severity : Sec/Soft File : scGantryInMail.c Line# : 1206 Function : SYSTEM MONITORING : HVDC Monitor Scan Type : None/Unknown Scan: 0/0/0 Gantry Service Switch is Disabled. Error: 245190 System aborted Axial scanning. No views, either offset or data, were collected/received. Data views expected: 992 See the Long Description for the full error code. Thu Jan 13 06:58:23 2005 Error: 245190 Host: ct02 Process: scanmgr File: scan_complete.cxx Line: 303 Function: System Control : Scan Control Scan Type: Axial Scan: 0/0/0 Scan Seq Id: 100
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required