GE Healthcare · CTLightSpeed214080242941831825000144858183365
LightSpeed 4.X - GOC2
Symptom
Scanner Hardware Stopped Scan. Scanner Hardware Stopped Scan
Error message
Error: 214080 HVDC Bus voltage is present while Backup Contactor pilot relay indicates a de-energized state. Gentry I/O relays K251 and K245 are energized . HVDC Bus voltage : 35 Mon Mar 27 09:40:09 2006 Host : OBC Error: 214080 File: OBC diag HW Checks.c 1.36 Line: 297 Function: Diagnostics XRAY GENERATION : HVDC Backup Contactor Intlk Test Name: HV Backup Times UniqueID: 738 Iteration : 1 Exec Level: Hard Time : 24294 Error Type: Hardware HVDC Bus voltage is present while Backup Contactor pilot relay indicates a de-energized state. Gentry I/O relays K251 and K245 are energized . HVDC Bus voltage : 35 Genty I/O address FFAFBFH Bit: D4 Expected : 1 Actual : 0 May also see the following error in gesyslog: Mon Aug 16 14:39:13 2004 Error: 183182 Host: OBC Process: Generator File: gen rotor.c 1.39 Line: 498 Function: SYSTEM POWER CONTROL : HVDC Control Scan: 1935/1/1 Type: Axial Exception Level: Pri/Most Severe Time: 14:39:13:450 Log Series: 45 I/O board pilot relays are closed. PDU pilot relay not energized. BCSTAT = 0 HVDC Rail voltage = 195V Gentry I/O address: FFAFBFH Bit: D4 Expected: 1 Actual: 0 This error is flagged by the OBC Process: Generator on the HVDC Control during High V
Applies to
- Models
- LightSpeed
- Product
- LightSpeed 4.X - GOC2 405L.8_H4.2M4 LightSpeed 4.X with GOC2 and MDAS 16 Gantry H4 Gantry Model # 2339985 and Global Operator Console 2 Model #'s 2366438 and 2366438-2(Hino) with HP8000 CPU (or newer) and Pegasus Recon ICE Box Product: LightSpeed16 405L.8_H4.2M4 CPU: GenuineIntel Intel(R) Xeon(TM) CPU 2.66GHz 4 2657 MHz i686 Processors Main memory size: 2048 Mbytes [root@presbyct2]# sg_map -i /dev/sg0 /dev/sda SEAGATE ST336753LW HPS2 /dev/sg1 /dev/sdb SEAGATE ST373453LW HPS1 /dev/sg2 /dev/sdc SONY SMO-F551-SD 1.05 /dev/sg3 /dev/scd0 MATSHITA DVD-RAM SW-9574S AZX8 /dev/sg4 /dev/scd1 HL-DT-ST DVD-ROM GDR8163B 0B15 [root@presbyct2]# df -h Filesystem Size Used Avail Use% Mounted on /dev/sda2 4.0G 1.7G 2.3G 41% / /dev/sda1 27M 12M 14M 44% /boot none 1008M 0 1007M 0% /dev/shm /dev/sda6 14G 3.5G 10G 25% /usr/g /dev/sda7 9.8G 753M 9.0G 8% /usr/g/sdc_image_pool /dev/sdb1 68G 28G 40G 41% /usr/g/sdc_image_pool2 Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 2133533-3 CAPACITOR, 4600UF, 450V, 14A, 85DEGC Quantity 2 required See Long Description for details 2133533-3 Capacitor, 4600 uf, 450v, 85 deg, Quantity 2 required and replace both if you suspect either one has failed or causing problems. Part #: 2133533-3 Part Type: GP CONSUMABLES Part Weight: 2.27 LBR Repairable: No Returnable: No Hazardous Material: N Description: CAPACITOR, 4600UF, 450V, 14A, 85DEGC FRU: Yes Status: Orderable Parts Offered as: Current: 2133533-3 Harvested: Not Available Exchange: Not Available Comments: FLS - 4600DF, 450V, 14A, 85 DEGREE CU/O COMPACT PDU RHAPSODE CAN SOURCE FROM ON-LINE. MS4636 11/7/96
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.