Scanner stopped scan with a popping noise from the YMS HiSpeed gantry

Symptom

Scanner stopped scan with a popping noise from the YMS HiSpeed gantry See Long Description Scanner hardware stopped scan during patient exam with a popping noise from the gantry and TGP Errors 60 - 0504H, 60 - 0314H & 20-1001-43 found in the log Error code: 60-0504H Message/explanation: Inverter Gate Power Supply error gate supply voltage has dropped below the level required to drive the IGBTs properly Potential cause: 1. Inverter (gate command board) 2. kV control board 3. Generator input voltage too low or line impedance too high Recommended action/Troubleshooting guide: Run HV power diagnostics Error code: 60-0314H Message/explanation: ILR Current time out. The current resonant frequency is lower than expected Potential cause: 1. kV control 2. Inverter 3. Current measurement circuit. Recommended action/Troubleshooting guide: Run HV power diagnostics. ERROR DETECTED BY OGP BOARD Scout Scan Error: 43 Code: 20-1001-43 Name: X-ray On Response Time Out. Class: Error Description: HV ON was not activated by JEDI on Scout Scan after EXPCMD was activated by OGP. Potential Cause / FRU: High possibility on JEDI in case with XG error.; In case without XG Error, JEDI (kV control or CT-IF) and interface between JEDI and OGP

Error message

Error: 60-0314H ILR Current time out. The current resonant frequency is lower than expected Error code: 60-0314H ILR Current time out. The current resonant frequency is lower than expected See the long description for the full error code Error code: 60-0314H Message/explanation: ILR Current time out. The current resonant frequency is lower than expected Potential cause: 1. kV control 2. Inverter 3. Current measurement circuit. Recommended action/Troubleshooting guide: Run HV power diagnostics.

Applies to

Models
HiSpeed
Product
HiSpeed YMS Series HiSpeed Series DXi, FXi, LXi, ZXI, and NXI Including Single / Twin detector and Glass / Metal Tubes. See Long Description for Details Subsystem/Components DXI (NP) FXI,LXI (NP+) ZXI (NP++ NXI (NP+ Twin NXI (NP++ Twin OC O2 running Unix or upgraded to Linux PC Gantry Alighnment Lights Halogen Laser Laser Laser Laser Mechanics Common Electronics firmware is different twin Det/Das Twin Det/DAS Table IMS no Yes Yes Yes Yes Generator Jedi Jedi NP++ Jedi Jedi NP++ Jedi Tube D3142T D3142T D3152T D3142T D3152T PDU Common Options List for V/R 5.5, 6, 7, 9, and 10 System 3D Power 440ma Max Image Disk 20000 Smart Prep Fast Scam 0.7 sec Performix 530 cooling Smart Recon Fast Scan 0.8 sec Asymmetric Scan SmartView Fast Scan 1.0 sec Cardiac gating DemtaScan Helical 30 Max Smart Addition Navigator Helical 60 Max Respiratory Gating Helical Plus Helical 120 Max Reformat Cpmmect {rp Raw Data 1000 max VolumeRendering2 ImageDosk Remote Tilt CT Colono Pioneer Mod Enhanced Cooling The following Options name changes Option (V5.5x,V6.0x,V7.x,V9.x,V10x) Option (V8.1x and V11.x) 3D >> Volume Analysis2 Navigator >> Navigator2,VolumeRendering2,VolumeAnalysis2 CtPerfusion >> CTPersusion2 Reformat >> Functool Options V8.1x and V11.x VolumeAnalysis2 Power 440ma ImageDisk 2000 Helical Plus Smart Prep Fast Scan 0.7 sec Performix 530 cooling Connect Pro Smart Recon Fast Scan 0.8 sec Asymmetric Scan ImageDisk SmartView Fast Scan 1.0 sec Cardiac Gating Pioneer MOD* DentaScan Helical 30 Smart Addition Power 200 ma max Navigator2/VolumeRendering2/ VolumeAnalysis Helical 60 Respiratory Gating Power 250 ma Max Power 300 ma Max Helical 120 Thickness 0.5mm CTColon Power 350 ma Max Raw data 1000 CtPerfusion2 AdvVesselAnalysis Remote Tilt Extended FOV Functool Enhance Cooling Performix Tube VolumeRendering2
Component
5133342 Inverter capacitor assembly for NP1.5 (Replaces 2229505-2) used onYMS JEDI GENERATOR See the long description for part identification 5133342 Inverter capacitor assembly for NP1.5 (Replaces 2229505-2) used onYMS JEDI generator Part #: 5133342 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: FRU FOR INVERTER CAPACITOR ASSEMBLY FOR NP1.5 FRU: Yes Status: Orderable Part #: 2229505-2 Part Type: GP CONSUMABLES Part Weight: 11.99 LBR Repairable: No Returnable: No Hazardous Material: N Description: INV CAPACITOR ASSEMBLY FRU: Yes Status: Orderable Comments: FLS - INV CAPACITOR ASSEMBLY YMS JEDI GENERATOR GELS - THIS PART IS ONLY FOR CT;FOR RAD ORDER: 2203900,CAPACITOR INVERTER