GE Healthcare · CTLightSpeedVCT26011824150000
LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
Scanner Hardware Stopped Scan. Scanner Hardware Stopped Scan
Error message
Error: 260118241 (80-0180) Rotation board communications problem. See LD for full error Wed Mar 2 16:58:01 2005 Error: 260118241 Host: orp Process: orp_subsys File: gen_exec.c Line: 2148 Wed Mar 2 16:57:59 2005 Host : Jedi Ermes # : 260118241 Exception Class : Abort Severity : Primary File : gen_exec.c Line# : 2148 Function : No System Function Reported Scan Type : Axial Scan: 50000/1/3 (80-0180)Rotation board communication problem. PPC board communication Watch Dog with Rotation board popped up because it did not get reply from Rotation board. Z6,Z7= 0h,0h Error: 260118241 (80-0180) Rotation board communication problem Code 80 Hardware Errors Error code: 80-0180H Message/explanation: Rotation board communication problem. PPC kV control board communication Watch Dog with Rotation board popped up because it did not get reply from Rotation board. Potential cause: Rotation board Control bus cable PPC kV control board Recommended action/ Troubleshooting guide: Verify the CAN cable between PPC kV control and auxiliary module is correctly connected to the Rotation board Check that rotation firmware is running (DS5 on rotation board blinking). If firmware OK, replace PPC kV control board.
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Component
- 2324118-3 VCT-JH4 Auxiliary Equipped. Aux Box See Long Description for details Part#:2324118-3 Part Type: GP CONSUMABLES Part Weight: 2.20 LBR Repairable: No Returnable: No Hazardous Material: N Description: VCT-JH4 AUXILIARY EQUIPED FRU: Yes Status: Orderable Comments: Set as Critical Part for Product CT_VCT, ms04278, 05Oct28 Added per VCT RSPL, ms13452 041205 Picture below
- Area
- CT