LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
Scanner hardware stops scan, with views collected - LESS THAN - Views expected See Long Description for more detail Scanner hardware stops scan, with Error: 245180 - views collected - LESS THAN - Views expected. & 260118311 Received command ignored. No action defined for current state This problem is seen more often on faster gantry rotations and during CTA (CT Angiography) studies. Error 245180 System aborted Helical scanning. The problem usually occurs when gantry is rotation at 0.4 seconds, the problem can sometimes be correlated to a specific protocol examples: CTA studies, Smartscore studies.
Error message
Error: 245180 System aborted Xray-on Static scanning. Wed May 12 13:54:02 2004 Error: 245180 Host: ctpro100 Process: scanmgr File: scan_complete.cxx Line: 313 Function: System Control : Scan Control Scan Type: Xray-on Static Scan: 0/0/0 Scan Seq Id: 1000 System aborted Xray-on Static scanning. Views expected 992 Views collected 0 an updated version of this error Wed Feb 9 14:53:22 2011 Error: 245180 Host: ct04 Process: scanmgr Function: System Control : Scan Control Scan Type: Helical Scan: 0/0/0 System aborted Helical scanning. Views expected 8762 Views collected 5555
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required