LightSpeed 7.x (VCT, VCT Select, Pro32)

Symptom

Cradle / IMS on GT1700 / GT2000 would not advance from home and makes grinding noise. See Long Description for more details and sound. Cradle / IMS on GT1700 / GT2000 would not advance from home and makes grinding noise This problem happen after moving a large patient off of the table, or after physically moving the IMS to it’s mechanical out of gantry limit (home). Attachment is the sound the table makes when the cradle move button is pushed. The button was pressed 2 times (2 sounds)

Error message

Error: 260134801 IMS command is canceled because of cradle unlatch See Long Description for complete error Error: 260134801 IMS command is canceled because of cradle unlatch. Fri Jun 27 22:04:59 2008 Error: 260134801 Host: tgp Process: tgp_subsys File: GtcbMotionGt.cxx Line: 90 Fri Jun 27 22:04:59 2008 Host : Table Sub-System Ermes # : 260134801 Exception Class : Secondary Severity : Pri/Soft File : GtcbMotionGt.cxx Line# : 90 Function : No System Function Reported Scan Type : None/Unknown Scan: 0/0/0 IMS command is canceled because of cradle unlatch.

Error: 260134802 IMS position is out of tolerance. See Long Description error messages Thu Oct 20 08:01:13 2005 Error: 260134802 Host: tgp Process: tgp subsys File: gtcb movechk.cxx Line: 581 Thu Oct 20 08:01:13 2005 Host : Table Sub-System Ermes # : 260134802 Exception Class : Secondary Severity : Pri/Soft File : gtcb movechk.cxx Line# : 581 Function : No System Function Reported Scan Type : None/Unknown Scan: 0/0/0 IMS position is out of tolerance. current position(um) : 398728 target position (um) : 0 start position (um) : 398728 velocity (um/s): 100000 time from start (ms) : 300

Applies to

Models
LightSpeed, VCT
Product
LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
Area
CT

Full cause & step-by-step resolution