LightSpeed 4.X - GRE

Symptom

A Loud noise is coming from the table, even when it is not moving. A loud "moaning" sound is coming from the table. The sound is fairly constant and does not seem to vary when the table it elevated or the cradle is moved in and out. The sound seems to come from the base of the table, farthest away from the gantry.

Applies to

Models
LightSpeed
Product
LightSpeed 4.X - GRE See Long Description for detailed information - H2_P_M16 Product Name: LightSpeed 4.X with GRE Product Photographs GE HEALTHCARE Method of remote or software identification - See attachment below for a complete list of software commands and typical results 1. check_config 2 . swhwinfo “swhwinfo” will have the following switches: · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da List of Supported Console types: GOC3 (GRE) GOC4 (GRE) List of software the product can run: 07MW11.10 SP2.0, SP3.0, SP3.1 FAQ's Table weight limit - 180 kg (400 lbs) normal operation - 205 kg (450 lbs) maximum allowed with decreased accuracy Tube type - D3186T D3186T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Component
46-229455P1 ETC POWER SUPPLY FAN See long description for details Part #: 46-229455P1 Part Type: GP CONSUMABLES Part Weight: 1.36 LBR Repairable: No Returnable: No Hazardous Material: N Description: FAN FRU: Yes Status: Orderable Parts Offered as: Current: 46-229455P1 Harvested: Not Available Exchange: Not Available Comments: FLS - 115VAC 40 CFM ETRI MOD 99 99XU2182. SPECIAL PRICING PER SERVICE MARKETING 6/92 ** ONE USE IS LIGHTSPEED ONE USE IS CTI
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.