Scanner Hardware Stopped Scan
Symptom
Scanner Hardware Stopped Scan. Scanner Hardware Stopped Scan
Error message
Error 230000036 Active view data stopped with less data acquired than expected See long description for full error Wed Apr 23 21:20:26 2008 Error: 230000036 Host: ice Process: dataacq File: dc_actions.cxx Line: 2096 Function: Data Acquisition : Scan Data Acquisition Scan Type: Axial Scan: 9044/2/5 Scan Seq Id: 9000 Active view data stopped with less data acquired than expected. Only the acquired data will be saved. Expected active view data: 5e2f48h bytes Acquired active view data: 41418h bytes Missing active view data: 5a1b30h bytes Scan aborted. Error: 260002447 Questionable DAS Channel Detected. DAS Output View Data did NOT Pass Selftest Tue Apr 12 17:45:37 2005 Error: 260002447 Host: DAS Process: DCB Firmware File: dcvtst.c Line: 791 Function: DATA ACQUISITION : Scan Data Acquisition Scan: 50043/1/0 Type: None/Unknown Exception Level: Pri/Soft Time: 17:45:37:060 Log Series: 32 Questionable DAS Channel Detecte 260002447 Questionable DAS Channel Detected. DAS Output View Data did NOT Pass Selftest Tue Apr 12 17:45:37 2005 Error: 260002447 Host: DAS Process: DCB Firmware File: dcvtst.c Line: 791 Function: DATA ACQUISITION : Scan Data Acquisition Scan: 50043/1/0 Type: None/Unknown
Applies to
- Models
- LightSpeed
- Product
- LightSpeed 2.X (Plus, QX/i) - Octane Always S-DAS 2.4.2_H2.4M5 LightSpeed 2.X (Plus, QX/i) - Octane (Pegasus or Rhapsode IG) - Always S-DAS Method of visual identification Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config List of Supported Console Types Octane with Pegasus Recon hardware. List of softwares the product can run 2.4.2_H2.4M5 FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3186T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 FEATURES/OPTIONS STD/OPTION Cat # Digital Laser Camera I/F B7700PD Smart Helical (s/w only) Standard B7530TK Fast Recon (s/w only) Option B7700JF BMD (requires B7710MP or MN) Option B7710MK Smart Prep Option B7530SP Smart Score ? ? 3D Analysis (Requires D3D) Option B7540TD Navigator (s/w only) Option B7540N DentaScan (s/w only) Option B7540SD Direct 3D (Requires B7710SA) Option B7810SS HIS/RIS Option (h/w and s/w) Option B7500PN Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required