GE Healthcare · CTLightSpeedVCT183179
LightSpeed 3.X (Ultra, Plus, QX/i) - GRE
Symptom
Scanner Hardware Stopped Scan. Scanner Hardware Stopped Scan
Error message
Error: 183179 I/O board sensed external x-ray interlocks not satisfied. Sun Sep 5 11:10:28 2004 Error: 183179 Host: OBC Process: Generator File: gen_control.c 1.39 Line: 658 Function: XRAY GENERATION : Xray Exposure Interlocks Scan: 4167/1/1 Type: Scout Exception Level: Pri/Soft Time: 11:10:29:165 Log Series: 41 I/O board sensed external x-ray interlocks not satisfied. Possible causes: - Scanning room door is open (if applicable). - Check relay on DIP and/or Axial board. This error is flagged by the OBC on I/O board during xray generation.
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 3.X (Ultra, Plus, QX/i) - GRE Always 4 or 8 slice MDAS. H2_P_M4 H2_P_M8 LightSpeed 3.X - GRE Method of visual identification Small rounded gantry similar in appearance to LS 2.X and 4.X. Always has an MDAS4 or MDAS8 Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da Always has an MDAS4 or MDAS8 List of Supported Console Types GOC3 Will have a DARC, SDDA and IG GOC4 Will have a DARC 2 and IG List of softwares the product can run 07MW11.10 SP3 06MW29.7 - obsolete 06MW03.5 - obsolete 05MW14.5 - obsolete 04MW44.9 - obsolete 04MW13.7 - obsolete FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3186T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 2253562 EIGHT SLICE DAS CONTROL BOARD also used on MDAS 4 See Long Description Part #: 2253562 Part Type: GP CONSUMABLES Part Weight: -13639.86 KGM Repairable: No Returnable: No Hazardous Material: N Description: EIGHT SLICE DAS CONTROL BOARD FRU: Yes Status: Orderable ====================== Parts Offered as: Current: 2253562 Harvested: Not Available Exchange: Not Available Comments: FLS - EIGHT SLICE DAS CONTROL BOARD.USED ON WARP3. SUPPLIER IS SCI. MSA6724 EJM 05/16/01 COLLECTION OF DEFECTIVES START7/23/01 MS5277 TAKEN OFF RECYCLING PROGRAM PER L.BENIWAL (MSA8429 08/20/02) GELS - LIGHTSPEED ULTRA DCB / OPTIC FIBER FREQ 33 MHZ / NEEDS DIP BOARD REF 2259530 PDB 02/01/21 DNA FOR A REWORK TO PURGE MATERIAL FOR QUALITY ISSUE PER REQUEST O CT ENG/A REGAL 03/01/20,DAS CONTROL BOARD
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.