GE Healthcare · CTLightSpeed26011201513070

LightSpeed 5.X (60kW)

Symptom

Customer was not able to remote tilt gantry. In many cases , gantry will tilt from the Gantry Controls.

Error message

Error: 260112015 The Gantry Touch Sensor FAULT ( error text varies ) See long description for error examples Error text varies. Tue Sep 4 10:28:17 2007 Error: 260112015 Host: tgp Process: tgp_subsys File: uif_table_tilt_mgr_gt.c Line: 9075 Tue Sep 4 10:27:02 2007 Host : Table Gantry Processor Ermes # : 260112015 Exception Class : Secondary Severity : Pri/Soft File : uif_table_tilt_mgr_gt.c Line# : 9075 Function : PATIENT ANATOMY POSITIONING : Tilt Drive Scan Type : None/Unknown Scan: 6891/2/0 The Gantry Touch Sensor FAULT. Gantry Sensors: BACK Touch Sensor Error(s). Gantry Controls are running in FAULT MODE. Operator's Console Remote Tilt button is DISABLED. Use local gantry controls to tilt the gantry Sat Nov 17 00:07:55 2007 Error: 260112015 Host: tgp Process: tgp subsys File: uif table tilt mgr gt.c Line: 13070 Sat Nov 17 00:07:54 2007 Host : Table Gantry Processor Ermes # : 260112015 Exception Class : Secondary Severity : Pri/Soft File : uif table tilt mgr gt.c Line# : 13070 Function : PATIENT ANATOMY POSITIONING : Tilt Drive Scan Type : None/Unknown Scan: 0/0/0 The Gantry Touch Sensor FAULT. Gantry Sensors: FORWARD Touch Sensor Error(s). Gantry Controls are running in FAULT MO

Applies to

Models
LightSpeed
Product
LightSpeed 5.X (60kW) LightSpeed 5.X (60kW) ~ Use with MDAS or GDAS HP_P_G4 HP_P_G8 HP_P_G16 HP_P_M16 LightSpeed 5.X 60KW G-DAS16 with GRE Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Component
2277405 Front / Small Gantry Tilt Forward Sensor / Interference Switch used on H2 gantry See Long Description for Details 2277405 Front / Small Gantry Tilt FORWARD Sensor / Interference Switch used on H2 Part #: 2277405 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: PATIENT SENSOR, SMALL FRU: Yes Status: Orderable Comments : FLS - SAFETY TILT INTERFERENCE SWITCH FRONT USED ON H2 COMMON TO MFG. MS26561 DSM 1/7/01 COLLECTION OF DEFECTIVES START7/23/01 MS5277 FLS - PLEASE CONVERT SPH ORDER TO OVERNIGHT SHIPMENT IF PART AVAILABLE IN MEMPHIS AND IF FEDEX SERVICE (INCLUDING 8:00 AM SERVICE) MEETS FE NEED TIME CRITERIA
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.