LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
Site cannot send a specific exam or series to PACS or other dicom hosts. All other exams send without error. See Long Description for more details Site cannot send a specific patient to PACS or other dicom host. All other exams send without error. Error as seen in the GESYSLOG Fri Apr 7 19:00:01 2006 Error: 11046 Host: fchct1 Process: dcserver File: dcspush.c Line: 1381 STORE response received with refused status (0xA700) - Aborting! Fri Apr 7 19:00:01 2006 Error: 11009 Host: fchct1 Process: dcserver File: dcspush.c Line: 1516 Association was aborted with PACS_Live Fri Apr 7 19:00:01 2006 Error: 11080 Host: fchct1 Process: dcserver File: dcscommon.c Line: 242 Connection error: 11283 (PACS_Live) Error as seen in the DCSLOG MESSAGE from Process 1937>> Fri Apr 7 19:00:01 2006 (dcspush.c:1381) [Dcserver]> STORE response received with refused status (0xA700) - Aborting! MESSAGE from Process 1937>> Fri Apr 7 19:00:01 2006 (dcspush.c:1516) [Dcserver]> Association was aborted with PACS_Live MESSAGE from Process 1937>> Fri Apr 7 19:00:01 2006 (dcscommon.c:242) Connection error: 11283 (PACS_Live)
Error message
Error: 11046 STORE response received with refused status (0xA700) - Aborting! See LD for full text. Error: 11046 STORE response received with refused status (0xA700) - Aborting! Error as seen in the GESYSLOG Fri Apr 7 19:00:01 2006 Error: 11046 Host: fchct1 Process: dcserver File: dcspush.c Line: 1381 STORE response received with refused status (0xA700) - Aborting! Error as seen in the DCSLOG MESSAGE from Process 1937>> Fri Apr 7 19:00:01 2006 (dcspush.c:1381) [Dcserver]> STORE response received with refused status (0xA700) - Aborting!
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required