Pular para o conteúdo principal
GE Healthcare · CTLightSpeed200002632

OPTION STATUS LOG message "All FlexTrial Options are uninstalled

Symptom

OPTION STATUS LOG box popped up on screen "All FlexTrial Options are uninstalled and the user can no longer use these options" See Long Description for Details and pop up attention box. Option status log box popped up on screen "All FlexTrial Options are uninstalled and the user can no longer use these options" with Error: 200002632 System Back dated. SW Options will be disabled.

Error message

Error: 200002632 System Back dated. SW Options will be disabled. See Long Description for Details. Mon Dec 31 18:03:15 2001 Error: 200002632 Host: darc Process: dataacq File: swokutl.cxx Line: 784 *** Error: System Back dated. SW Options will be disabled. Please change the system date to current date or contact OLC

Applies to

Models
LightSpeed
Product
LightSpeed 4.X - GRE See Long Description for detailed information - H2_P_M16 Product Name: LightSpeed 4.X with GRE Product Photographs GE HEALTHCARE Method of remote or software identification - See attachment below for a complete list of software commands and typical results 1. check_config 2 . swhwinfo “swhwinfo” will have the following switches: · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da List of Supported Console types: GOC3 (GRE) GOC4 (GRE) List of software the product can run: 07MW11.10 SP2.0, SP3.0, SP3.1 FAQ's Table weight limit - 180 kg (400 lbs) normal operation - 205 kg (450 lbs) maximum allowed with decreased accuracy Tube type - D3186T D3186T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Area
CT

Full cause & step-by-step resolution