Pink Pop Up Message saying The system has been configured for a Performix Tube for 30 days
Symptom
Pink Pop Up Message saying The system has been configured for a Performix Tube for 30 days. See Long Description for full text of message. Pink Pop Up Message saying The system has been configured for a Performix Tube for 30 days Tube type at the end of the first sentence in message below can vary. The system has been configured to recognize a GE Medical Systems Tube. A 30 day period from the date of tube installation has been granted to allow time to manually verify the tube identity. Please call GE Medical Systems to dispatch a Field Service Engineer (FSE) to verify the tube configuration. Please allow a minimum of 10 days for the FSE to schedule verification. Verification should take no more than 30 minutes. If a GE Medical Systems FSE does not verify the tube identity within %s days, the system will revert to an "unrecognized tube" status, resulting in the following: - GE Medical Systems cannot assure that the system performance will conform to specifications. - Advisory messages will be posted to the operator about an unrecognized tube during system startup, during tube warm-up, during Fast Calibration, and in the dose report.
Error message
Error: 244646 the system will revert to "unrecognized tube" status See long description for full error Tue Apr 10 21:07:28 2007 Error: 244646 Host: ct02 Process: fwmgr File: tubeApprovalPopupMgr.cxx Line: 259 Tube verification reminder: If a GE Medical Systems FSE does not verify the tube identity within 30 days, the system will revert to an unrecognized tube" status.
Applies to
- Models
- BrightSpeed, VCT
- Product
- BrightSpeed HPower, Delight, Velocity or MERI HPower HP_P_G4_G_HPT Excel HP_P_G8_G_HPT Edge HP_P_G16_G_HPT Elite HP_P_G16_G_GMV Elite HP_P_P16_G_GMV Elite HP_P_M16_G_HPT BrightSpeed Method of remote software hardware identification check_config swhwinfo List of Supported Console Types : HP_P_G16_ G _HPT Note: G could be GRE, AIO or TIO - check with: cat /usr/g/config/INFO | grep CONSOLETYPE GOC4 AIO TIO List of softwares the product can run: 08BW20.1 07MW11.10 08BW44.1 ( Delight ) 09HW30.4 ( Velocity ) 09BW35.11 ( MERI - Pancake DAS ) FAQ's 1. All BrightSpeed Power Systems use the Performix tube D3186T HP_P_G4_G_HPT (Excel - H-Power Table) HP_P_G8_G_HPT (Edge -H-Power Table ) HP_P_G16_G_HPT (Elite -H-Power Table ) HP_P_G16_G_GMV (Elite -Global Table Mid Value - modified GT1700 no IMS ) Note: G could be GRE, AIO or TIO (check with: cat /usr/g/config/INFO | grep CONSOLETYPE ) BrightSpeed Elite Power Systems will only be sold as Velocity System starting in 2Q/2010. Delight Elite Power being phased out 1Q/2010 BrightSpeed Power 4 & 8 slice systems have been discontinued due to restructuring of the product lineup. Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required