What HC10810 means

On DryStar 5500 (Type 5364/100) and DryStar 5503 (Type 5364/300) CT systems, status code HC10810 indicates: Lower pick-up passed sensor S20 failure. The code originates in the Film Tray Pick-up — Sensors, Motors & Actuators section of the Film Tray Pick-up Modules (Sensors, Motors & Actuators). Severity level alarm (Alarm).

Reported action: Check the connections to S20, then connector XS5, then connector P31 on the MEC board, reconnecting or replacing any faulty connector found. Check the wiring from S20 to MEC/P31 with a multimeter and repair as needed. If the sensor is confirmed defective, power off the printer and replace S20; if the fault traces to the board, replace the MEC board..

Raised on the Drystar 5500/5503 when the lower pick-up "passed" sensor S20 is not connected or is malfunctioning. Filed in the pick-up module sensors/motors/actuators fault-code table with the equivalent upper- and middle-tray passed-detection codes.

Full troubleshooting for HC10810

The complete diagnosis, cause tree, and step-by-step remedy for the Film Tray Pick-up — Sensors, Motors & Actuators subsystem are documented in the FSELIB Activion16 (TSX-031A) service manual — re-authored, web-first, with real figures.

Open the Activion16 service manual

Related Film Tray Pick-up — Sensors, Motors & Actuators codes

Discuss HC10810 with other field engineers in the FSELIB forum

Source: AGFA DryStar service manual — HC error catalogue (FSELIB authored corpus). Reference information re-authored by FSELIB — not a copy of the OEM manual.