Pular para o conteúdo principal

Patient Support Intera Achieva

95 parts in the Philips Healthcare Patient Support Intera Achieva assembly — OEM material numbers, descriptions and compatibility.

PosMaterial No.DescriptionQtyFRU
—++PATIENT SUPP ELECPATIENT SUPP. ELECTRONICS——
e++452215021911p.l.c——
—++452215043101PLC-MT——
—++452213961331Patient Support Electronics Control Unit——
—++459800111781CONTROL-UNIT-MT2——
—++459800073191PLC Extension 2 Achieva——
—++459800014631servo amplifier——
—459800111791FAN CONTROL-UNIT-MT2——
a452215021983SHILDED FANS PSU AND CU——
g452215021951power supply 12V——
f452215021961power supply 24V——
h452215021971power supply 28V——
—452213309812POWER SUPPLY AMBIRING——
f452215021941resistor 1E 10W——
h242208601262UL-FUSE SB 19343 6,25A——
b242208601086UL-FUSE SB MDL 800MA 250V——
c242208601405fuse slow 1.25A 1/4x11/4"——
d242208601042UL-FUSE SB MDL 1A 250V——
j271217100044mains filter 10A 230VAC——
—++——
I242254941624filter feedthrough——
—452215021923SOLID STATE RELAY——
b242213206516Relay DILEM?10?G(24VDC)——
k242213503988safety help relay——
—452213173471dummy connector LCC1X5——
—++——
—++——
—++VERTICAL ACTUATORVERTICAL ACTUATOR ASSY——
—452215021803VERTICULAR ACTUATOR ASSY——
a452215021811capacitor 40uF——
—++——
—++HORIZONTAL DHORIZONTAL DRIVE UNIT——
—++459800111771horizontal motor assy——
—452215021852assy drive axis——
—452215038901TOOTHWHEEL HDU——
e452215021861horizontal encoder——
j452215021891mech. end stop buffers——
—242212802851service up switch——
l452215033951TTR SWITCH +BUTTON +BUSH——
m452215039221FLEXIBLE COUPLING——
—452215034521OPTICAL SENSOR PM-L54——
—++——
—++TABLE COVERSTABLE COVERS——
1452215034052STRETCHER——
2452215034061GRP UPPER COVER LEFT——
3452215034071GRP UPPER COVER RIGHT——
4452215034081SM UPPER COVER LEFT/RIGHT——
5452215034091SM UPPER COVER FRONT/REAR——
6452215034101MIDDLE COVER LEFT/RIGHT——
7452215034111MIDDLE COVER FRONT/REAR——
8452215034121LOWER COVER LEFT/RIGHT——
9452215034131LOWER COVER FRONT/REAR——
—452215033931ASSY PATCOM COVER——
10452215034141COVER PHYSIOLOGY——
11452215034151TROLLEY STOP——
12452215033941SET PLUGS TROLLEY STOP——
—++——
—++TABLE TOP (stat/t)TABLE TOP (static/trolley)——
—989603023612TABLE TOP-S-A——
a452213161924rack table top (static)——
—452215022271set mounting material——
—++——
—++CABLES-- CABLES --——
—452213175751cable assy (lcc1x3-mc1x1)——
—452213175771cable assy (lcx8-mvpx1)——
—452213175761cable assy (lcx4-m1l/m2l)——
—452213161214cable assy (lcc1x4-mc2x1)——
—452213175744CABLE ZX52A-LCX9——
—452213175373CABLE PP-X10 - MVP-X8——
—452213175173cable assy (ppx20-mc1x2)——
—452213175125cable assy (ppx12-mmx3)——
—452213306871CABLE PP-X9 - MU-X5——
—459800111801cable assy (lcc1x2-lhx2)——
—242254942361FIBRE CABLE 30M——
—452213161174cable assy (lcx7-lhx3)——
—452215021991cable assy——
—459800111811cable assy (lcc1X6-LH-X23)——
—459800111821cable assy LH-X23 - LH-X8/LH-X12——
—459800111831cable assy (LHX2-LHX3/LHX4/LHX5/LHX6/LHX7/LHX9/LHX10)——
—452213309781CABLE LC-X4 - LB-X8/LC-X4——
—452213311491CABLE LB-X7 - MCFL/MCFR——
—452213308931CABLE LCC1-X3 - MU-X7——
—452213175331cable assy (mvpx1-ls1/s3)——
—++——
—++——
—452213190762TTE PLATE ASSY——
—452219507731TTE PLATE MECHANICS——
—452213190772BEARING PLATE ASSY——
—452213214091SET MOUNTING MATERIAL TTE——
—452213214102HEAD REST TTE——
—452213214112LEG SUPPORT TTE——
—452214233511Arm Support (2 pcs)——
—452209008831Nurse call——
—452213214122TTE STORAGE RACK——
—++——

Working on this equipment?

The part number above is free. A FSELIB subscription adds what you need to actually do the job on Patient Support Intera Achieva:

  • Exploded-view diagrams with clickable hotspots — find the part on the drawing instead of guessing.
  • Service manuals for the system this part belongs to — removal, installation and calibration procedures.