Pular para o conteúdo principal

RF Coils 0.5T

111 parts in the Philips Healthcare RF Coils 0.5T assembly — OEM material numbers, descriptions and compatibility.

PosMaterial No.DescriptionQtyFRU
d452213083611KNOB1—
e452213083691BINDING STRAP (18CM)1—
f122200198299BINDING STRAP (HOOK)1—
g452213115421TMJ COIL (LEFT) T5/T5-NT1—
h452213115431TMJ COIL (RIGHT) T5/T5-NT1—
n452213115201TULE CABLE TRAP1—
—++——
—989603003141ASSY.CIRC.COIL T5-NT C11—
—452210483272PIN CONNECT0R 6P+1C1—
—++——
—989603003151ASSY.CIRC.COIL T5-NT C31—
—452210483272PIN CONNECT0R 6P+1C1—
—++——
—989603003161CIRCULAR COIL C4 T5-NT1—
—452210483272PIN CONNECT0R 6P+1C1—
—++——
—989603003171EXTREMITY COIL E1 T5-NT1—
—452210483272PIN CONNECT0R 6P+1C1—
—++——
—989603003181RECTANGULAR COIL R1 T5-NT1—
—452213014171BINDING STRAP (POSITION)1—
—452210483272PIN CONNECT0R 6P+1C1—
—++——
—989603003131WRAP AROUND COIL T5-NT1—
—452210483272PIN CONNECT0R 6P+1C1—
a252240114015nut M8 PA1—
b452213198621Adjustable foot QNC1—
c452213087083SLIDING RING1—
d252218774066csk-hd scr M3x8 AL1—
e452213087165CABLE ASSY (RING DRIVER)1—
f452213087176QNC CONNECTION CABLE1—
g452210483272PIN CONNECT0R 6P+1C1—
h452213115201TULE CABLE TRAP1—
i452213150811COIL CARRIER QNC1—
—452213124833CABLE TRAP QNC (T5/T5-NT)1—
—452210483272PIN CONNECT0R 6P+1C1—
—++——
—452213086705BREAST COIL 0.5T1—
—452213087561B.C.SAM FANTOOMHOUDER1—
—452213086735BREAST COIL HEAD REST1—
—452213168632BREAST COIL MATTRESS (mushroom1—
—452212586961non skid strap1—
—452213156502BREAST COIL CONN. CABLE1—
—452210483272PIN CONNECT0R 6P+1C1—
—++——
—989603008462KNEE Q COIL T5-NT1—
—452215010591COIL CARRIER (T5/NT)1—
—452215010571COMFORT PAD1—
—452215010581PHANTOM SUPPORT PAD1—
—452210483272PIN CONNECT0R 6P+1C1—
—452215014421POSITIONING FOOT-PIN1—
—452213179251spare clip for knee coil1—
—++——
—452213156613QTL SPINE COIL II T5-NT——
—452213123484BINDING STRAP (SET)1—
—452213128332cable clip1—
—452213086451ECG HOLDER1—
—452213086515FLUX PROBE HOLDER1—
—452213094285L-CABLE QTL1—
—452213168622QTL MATRESS (mushroom)1—
—452213089231qtl phantom1—
—452213094342T-CABLE QTL1—
a452213086113POSITIONING PIN1—
a252218774088screw for posit. pin m4x81—
b452213086856QTL GUIDING SHAFT1—
—452213189231MARKER QTL COIL1—
d452213156511QTL CONNECTION CABLE1—
e452210483272PIN CONNECT0R 6P+1C1—
—++——
—989603000642ENDOCAVITARY COIL T5/T5-NT1—
—452213115152Coil holder for SPT1—
—452213126024ENDO COIL PRE AMP CARD1—
—452213115524ENDO COIL CONNECTION CABLE1—
—452210483272PIN CONNECT0R 6P+1C1—
—++——
—452213107682SAM HOLDER TMJ COIL1—
a452213083511LOWER COVER1—
b452213029253HEADREST TMJ COIL1—
c452213029271HEAD BINDIND STRAP1—
—452213123357QUAD. HEAD COIL T5-NT——
1452213194901ONDERBAK QHC NON_LOAD1—
2452213139634HEAD REST WITH CUSHION1—
3452213086074CUSHION SET Quad Head Coil1—
4452213059972GUIDE POST1—
5452213081242COUPLING PIECE1—
6452213083641PIN 11—
7452213059954guidepost locking pin1—
8452213059962STOP BLOCK1—
9452213029887QHC CONNECTION CABLE1—
10452210483272PIN CONNECT0R 6P+1C1—
11452213083652PIN 21—
12122200198299BINDING STRAP (HOOK)1—
13452213029951CHIN STRAP1—
15452213029897CABLE ASSY (MIRROR DRIVER)1—
—452213115201TULE CABLE TRAP1—
—252218728114countersunk screw PA M5x101—
—++——
—452213150831QUAD NECK COIL II T5/T5-NT1—
—122200198299BINDING STRAP (HOOK)1—
—452213107482FOAM PLATE (0.53X0.68M)1—
—452213087074GUIDE STRIP QNC1—
—452213113741PILLOW 1 (0.25X0.16M)1—
—452213113751PILLOW 2 (0.29X0.16M)1—
—452211717552QNC DRIVER CARD NT/T51—
—452213150893QNC HEAD REST II1—
—452213107491QNC HEAD SUPPORT1—
—452213096091QNC PHANTOM HOLDER1—
—452213107471QNC SHOULDER SUPPORT1—
—452213107471QNC SHOULDER SUPPORT1—
—452213113731STRAP LONG (0.36M)1—
—452213113721STRAP SHORT (0.3M)1—

Working on this equipment?

The part number above is free. A FSELIB subscription adds what you need to actually do the job on RF Coils 0.5T:

  • Exploded-view diagrams with clickable hotspots — find the part on the drawing instead of guessing.
  • Service manuals for the system this part belongs to — removal, installation and calibration procedures.
  • Error codes with meaning, severity and the subsystem that reports them.