Ilinq checkout failure : Error while downloading all files, Failed to transfer in ACTIVE mode, Failed to put t…
Xeleris:Ilinq checkout failure
Symptom
Ilinq checkout failure : Error while downloading all files, Failed to transfer in ACTIVE mode, Failed to put the file
Error message
Error while downloading all files:com.ge.med.service.ilinq.util.FTPException: Failed to put the file : Socket is closed Log capture: The iLinq Checkout will now execute instruction(s) specific for XELERIS2, please wait. Starting a FTP Session to 172.18.100.171. Starting a Telnet Session to 172.18.100.171. Downloading the file /eaw/download/II_DWNLD/II_heartbeat/HeartBeatClient.class Downloading the file /eaw/download/II_DWNLD/II_heartbeat/HeartBeatMobileClient.class Downloading the file /eaw/download/II_DWNLD/II_heartbeat/hbt.conf Downloading the file /eaw/download/II_DWNLD/II_backup/.backup Performing instructions finished. SIGMA: Performing instructions finished at: 11-Feb-08 11:42:17 Starting Global Phone Page download. Please wait... sending command: chmod of all downloaded files to 777. -- expecting (insite>) Done of chmod! Downloading the Phone page files from /eaw/download/II_DWNLD/II_phone/USA Downloading the file /eaw/download/II_DWNLD/II_global/PhoneNumServlet.class Downloading the image files from /eaw/download/II_DWNLD/II_global/images/zh Downloading the image files from /eaw/download/II_DWNLD/II_global/images/ja Failed to transfer in ACTIVE mode . Retrying transfer by
Applies to
- Models
- Infinia, Xeleris
- Product
- Infinia II Infinia II Acquisition System Infinia I Infinia I Acquisition System Ventri Ventri Ventri Infinia HE4 Infinia II Hawkeye 4 & Infinia II GP (Infinia running Windows XP software) Xeleris Xeleris Workstation Xeleris Workstation
- Component
- *Insite All aspects related to Insite Connectivity All aspects related to Insite Connectivity
- Area
- Nuclear Medicine
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare Nuclear Medicine issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare Nuclear Medicine issues
- Service Note 43783_1 Feb/08 Infinia/Ventri/Xeleris 1.1 & 2
- Xeleris 1.1 DVD-RAMs do not always load back on to the same system that created them
- Unable to display or transfer Xeleris patient data.
- How to restore/install Entegra/Xeleris Aladdin protocols
- After software upgrade FMI40786, the Infinia application does not automatically start on boot up
- I need the product data sheet on catalog E4500AK x-ray in use warning light interface control panel for Infinia