Pular para o conteúdo principal
GE Healthcare · CT26000240348361114001260012602

Lightspeed 1.X - Octane with O2 SBC

Symptom

"Scan hardware Stopped Scan" with DAS power errors. "Scan hardware Stopped Scan" with DAS power errors

Error message

Error: 260002403 The Data Acquisition System Has Detected An Error In The +/- 12V Analog DAS Power Supply. See Long Ddescription for error variation Thu Apr 13 06:29:45 2006 Error: 260002403 Host: DAS Process: DCB Firmware File: pwrtst.c Line: 178 Function: DATA ACQUISITION : Scan Data Acquisition Scan: 48361/2/4 Type: Axial Exception Level: Sec/Soft Time: 06:29:44:870 Log Series: 97 The Data Acquisition System Has Detected An Error In The +12V Analog DAS Power Supply.^B Measured: 0 mV, Expected range: 11400 to 12600 mV Mon May 19 00:25:21 2008 Error: 260002403 Host: DAS Process: DCB Firmware File: pwrtst.c Line: 233 Function: DATA ACQUSITION : Scan Data Acquisition Scan: 0/0/0 Type: None/Unknown Exception Level: Sec/Soft Time: 00:25:22:315 Log Series: 28 The Data Acquisition System Has Detected An Error In The -12V Analog DAS Power Supply.^B Measured: -12602 mV, Expected range: -12600 to -11400 mV

Applies to

Product
Lightspeed 1.X - Octane 10.5_2.8.2I_H1.3M4 10.4.1_2.8.2I_H1.3M4 - obsolete Lightspeed 1.X - Octane Method of visual identification Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config showprods|grep Apps note: if check_config does not work then the software is not up to date with all FMI's. Check FMI history and verify that all patches have been loaded since last software reload. Ref FMI 25269 List of Supported Console Types Octane with Pegasus Recon hardware. may have an 02 SBC - Run df -k to see if the sbc is partitioned. List of softwares the product can run 10.5_2.8.2I_H1.3M4 10.4.1_2.8.2I_H1.3M4 - obsolete FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3176T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare CT issues