Scan Aborts with EOS Error.Verify HFO3 SP1 is installed, wqr.HF OpenSpeed.2226578 PSD Programming Error.HFO3
Symptom
Scan Aborts with EOS Error Openspeed system running HFO3 M4. When customer uses the frfse-rpc PSD (intermittently) they will only get half the images reconstructed (only odds). This is because the scan has aborted. Then when they try to download the next series the TPS hangs and the customer has to reset TPS or reboot the system. Operator sees the message "Pulse Sequence Error Occurred". Message log has EOS and other errors logged. See attachments for the review screens and errors logged during these events. MRIhc02494 Openspeed system running HFO3 M4. When customer uses the frfse-rpc PSD (intermittently) they will only get half the images reconstructed (only odds). This is because the scan has aborted. Then when they try to download the next series the TPS hangs and the customer has to reset TPS or reboot the system. Operator sees the message "Pulse Sequence Error Occurred". Message log has EOS and other errors logged. See attachments for the review screens and errors logged during these events. MRIhc02494
Error message
2224944 Internal PSD Programming Error. PCT informed HPC that it had stopped, but its internal state indicates it is still running. 2224944 4 MRS2_OC0 NSPHPC_PORT_ID:hpc_rep_stop 560 Internal PSD Programming Error. It may be necessary to reset TPS. PCT informed HPC that it had stopped, but its internal state indicates it is still running. 2218537 Scan Stopped; a Pulse Sequence Error Occurred. 2218537 1 MRS2_OC0 scnMsaScanMgr.m 2430 Scan stopped, A pulse sequence error occurred. 2226578 PSD Programming Error: The PSD was still preparing a sequence when an EOS interrupt occurred. Lengthen TR or reduce the number of slices. 2226578 1 MRS2_OC0 NSPHPC_PORT_ID:eos_isr.c 5 PSD Programming Error: The PSD was still preparing a sequence when an EOS interrupt occurred. Lengthen TR or reduce the number of slices.
Applies to
- Product
- HF OpenSpeed HFO1 HFO2 and HFO3 Only.
- Software
- HFO3
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- Accidental Push of E-stop Button.
- CWA ID118772. Unable to Scan with PDU Error
- Unable to Scan with SSM HV Power Supply Low Errors on HDx System Due to SSM HV Power Supply.
- Abnormal gating signal from finger probe.
- CWA ID124838. Accidental Push of E-stop Button.
- Unable to Scan with SSM HV Power Supply Low Errors.