GE Healthcare · MRDiscovery22522932252310
Intermittent Dynamic Disable faults due to bad cables.
Symptom
Unable to Scan with Dynamic Disable Faults Unable to Scan with Dynamic Disable Faults.
Error message
2252293 The Driver Module Has Detected a Fault. Wed Apr 21 20:00:24 2004 Error: 2252293 Host: lx-mr Process: NSP File: SCP:DCB Line: 1986 The Driver Module Has Detected a Fault.^A Details of the Fault can be found in other error messages.-> 2252310 DD Driver Fault Detected - Open Circuit See Long Description for extended error message. Fri Oct 22 19:03:04 2004 Error: 2252310 Host: PRD_GE_MR03 Process: NSP File: SCP:DCB Line: 1429 DD Driver Fault Detected - Open Circuit. Source of Fault is BD2 (Dynamic Disable Boards at Front of Body Coil). Value = 3644 mV Limit: 2177 mV-> Extended Error: This usually indicates that a cable somewhere in the circuit path is not connected or one of the load diodes has failed open. Inspect the failing path. Use TR DD MC System Path diagnostic to troubleshoot. In HD/HDx Systems, BD1 is the Dynamic Disable Board at Front of Body Coil BD2 is the Dynamic Disable Board at Front of Body Coil BD3 is the Dynamic Disable Board at Back of Body Coil BD4 is the Dynamic Disable Board at Back of Body Coil In 20.0 and later systems, try running the TR DD System Path diagnostic to troubleshoot.
Applies to
- Models
- Discovery
- Product
- Discovery MR750. Also called DVMR. This product is compatible with 3.0T 20.0, 20.1_IB1, IB2, 21.0 and DV22.0 software only
- Software
- 20.1_IB1 and IB2 This release of software is applicable to Discovery MR450 and Discovery MR750 systems. See Long Description 20.1_IB1 is the unified Discovery MR450 and Discovery MR750 software release. Known internally to engineering as "DVIB". This release of software is applicable to Discovery MR450 and Discovery MR750 systems. 20.1_IB2 is the upgrade (bug fixes) for IB1.
- Component
- 5330932-28 Run M1314, MAG-DDSPLIT-J21 to MAG-BORE-J7 5330932-28 Run M1314, MAG-DDSPLIT-J21 to MAG-BORE-J7, DVw, 6250mm 5330932-27 Run M1313 MAG-DDSPLIT-J20 to MAG-BORE-J6 5330932-27 Run M1313 MAG-DDSPLIT-J20 to MAG-BORE-J6, DVw, 6250mm
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA How to Change Date or Time on LX, Excite, HD, HDe, HDx, HDxT, HFO, Excite HFO, Ovation1-4, Profile1-5, Discovery MR450 MR750 and Optima 450w Systems.
- CWA No Power to the Table and Magnet Display, Table Will Not Move And No Lights On the Magnet.
- CWA How to Change Exam Number from Remote Tools.
- Known Software issue with 15M4B coding error.
- Unable to Send Images to the PACS Due to PACS is down.
- U41 of the Slave RF Ctrl Assy, part of the PSU in the SRFD2 RF Amplifier Failed.