2252310 DD Driver Fault Detected - Open Circuit Due to RF Body Coil.
Symptom
Intermittent DD Driver Fault Open Circuit Faults Scan Aborts using Body or Surface Coils, Head Mode OK See Long Description. 2252310 DD Driver Fault Detected - Open Circuit. Source of Fault is BD1 (Dynamic Disable Boards at Front of Body Coil). Value = 4985 mV Limit: 4833 mV-> Extended Error: This usually indicates that a cable somewhere in the circuit path is not connected or one of the load diodes has failed open. Inspect the failing path. Use TR DD MC System Path diagnostic to troubleshoot. In HD/HDx Systems, BD1 is the Dynamic Disable Board at Front of Body Coil BD2 is the Dynamic Disable Board at Front of Body Coil BD3 is the Dynamic Disable Board at Back of Body Coil BD4 is the Dynamic Disable Board at Back of Body Coil In 20.0 and later systems, try running the TR DD System Path diagnostic to troubleshoot.
Error message
2252310 DD Driver Fault Detected - Open Circuit See Long Description for extended error message. Fri Oct 22 19:03:04 2004 Error: 2252310 Host: PRD_GE_MR03 Process: NSP File: SCP:DCB Line: 1429 DD Driver Fault Detected - Open Circuit. Source of Fault is BD2 (Dynamic Disable Boards at Front of Body Coil). Value = 3644 mV Limit: 2177 mV-> Extended Error: This usually indicates that a cable somewhere in the circuit path is not connected or one of the load diodes has failed open. Inspect the failing path. Use TR DD MC System Path diagnostic to troubleshoot. In HD/HDx Systems, BD1 is the Dynamic Disable Board at Front of Body Coil BD2 is the Dynamic Disable Board at Front of Body Coil BD3 is the Dynamic Disable Board at Back of Body Coil BD4 is the Dynamic Disable Board at Back of Body Coil In 20.0 and later systems, try running the TR DD System Path diagnostic to troubleshoot.
Applies to
- Models
- Optima
- Product
- Optima MR450W Wide bore magnet. Not Discovery750 or Discovery450.
- Software
- 21.0 Only for Optima MR450W (wide bore) systems. (Not to be used on Discovery MR450 or Discovery MR750). Only for Optima MR450W (wide bore) systems. (Not to be used on Discovery MR450 or Discovery MR750).
- Component
- 2208999-15 1.5T DVw Body RF Coil FRU- Blue and Black Case 2208999-15 1.5T DVw Body RF Coil FRU- Blue and Black Case
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA How to Change Date or Time on LX, Excite, HD, HDe, HDx, HDxT, HFO, Excite HFO, Ovation1-4, Profile1-5, Discovery MR450 MR750 and Optima 450w Systems.
- CWA No Power to the Table and Magnet Display, Table Will Not Move And No Lights On the Magnet.
- CWA How to Change Exam Number from Remote Tools.
- Known Software issue with 15M4B coding error.
- Unable to Send Images to the PACS Due to PACS is down.
- U41 of the Slave RF Ctrl Assy, part of the PSU in the SRFD2 RF Amplifier Failed.