Unable to find part number for Optima MR450w, Discovery MR450 and Discovery MR750 Arm Board Assembly.
Documentation is Wrong.
Symptom
Unable to find part number for Optima MR450w, Discovery MR450 and Discovery MR750 Arm Board Assembly. Part Number 51828221 from FRU Manual is not FRU See Long Description Unable to find part number for Optima MR450w and Discovery MR450 Arm Board Assembly. Part Number 51828221 from FRU Manual is not FRU. In the document entitled "Optima MR450w Field Replaceable Units (FRU)", Direction 5670005, Rev 2, which is found in Direction 5670000, Rev# 2, Optima MR450w 1.5T Service Methods, an incorrect part number is listed for the patient table's Arm Board. The part number listed in the illustration on page 21 is incorrect, however the correct part number for this part is listed on page 29 of the same document. Likewise, In the document entitled "Discovery MR450 & MR750 Field Replaceable Units (FRU)", Direction 5500105, Rev 5, which is found in Direction 5500113, Rev# 3 Discovery MR450 1.5T Service Methods, and in Direction 5500113, Rev# 3 Discovery MR750 3.0T Service Methods, an incorrect part number is listed for the patient table's Arm Board. The part number listed in the illustration on page 18 is incorrect, however the correct part number for this part is listed on page 26 of the same document.
Applies to
- Models
- Discovery, Optima
- Product
- Discovery MR450 Also called DVMR. This product is compatible with 1.5T 20.1, 20.1_IB1, IB2, 21.0 and DV22.0 software systems only.
- Software
- DV22.0 For the Discovery MR750, MR450 or Optima MR450w products only. For the Discovery MR750, MR450 or Optima MR450w products only.
- Component
- 5174186 Arm Board Assembly 5174186 Arm Board Assembly
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA How to Change Date or Time on LX, Excite, HD, HDe, HDx, HDxT, HFO, Excite HFO, Ovation1-4, Profile1-5, Discovery MR450 MR750 and Optima 450w Systems.
- CWA No Power to the Table and Magnet Display, Table Will Not Move And No Lights On the Magnet.
- CWA How to Change Exam Number from Remote Tools.
- Known Software issue with 15M4B coding error.
- Unable to Send Images to the PACS Due to PACS is down.
- U41 of the Slave RF Ctrl Assy, part of the PSU in the SRFD2 RF Amplifier Failed.