GE Healthcare · MRDiscovery226760022700322267728
unable to scan due to intermittent PDU PS1 48 V power supply failures.
Symptom
Unable to scan
Error message
2267600 - The IRF3 detected a fault on the fiber links. Status register See Long Description Error: 2267600 Host: LIBR-MR1 Process: NSP File: AGP:Irf3RrfHWO Line: 1418 Exception Class: Unknown Severity: Unknown The IRF3 detected a fault on the fiber links. Status register=0x%X The modules connected to these IRF3 jacks were determined to be the cause of the disruption: %s Extended Error: A momentary problem with any module connected to the DVMR dual fiber links can bring the links down for every node. The IRF3 can detect which link was the first to drop out. The module connected to that link should be the one who initiated the problem. If several modules dropped out at the same time the IRF3 will report multiple modules. In this case there might be a single problem effecting multiple modules such as a power supply glitch or a drop out on the shared reference clock source. Note: a problem on the RRX to ICN links will cause the RRX to IRF3 link to go down so errors reported against the RRX may be caused by a problem with an ICN. Possible cause(s): RRx Module, NB DTx Module, Img Compute Node, 2270032 - VRF detected RRX status issue Mon Sep 21 14:46:30 2009 Error: 2270032 Host: LIBR-MR
Applies to
- Models
- Discovery
- Product
- Discovery MR750. Also called DVMR. This product is compatible with 3.0T 20.0, 20.1_IB1, IB2, 21.0 and DV22.0 software only
- Software
- DV22.0 For the Discovery MR750, MR450 or Optima MR450w products only. For the Discovery MR750, MR450 or Optima MR450w products only.
- Component
- 5140621-4 48V Power Supply 1000W Condor PN GPMP 900_48 TEAL PN 0870109 5140621-4 48V Power Supply 1000W Condor PN GPMP 900_48 TEAL PN 0870109. Part is being set up for 3.0T DVMR program RSPL. 501139061, 5-Mar-08.
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA How to Change Date or Time on LX, Excite, HD, HDe, HDx, HDxT, HFO, Excite HFO, Ovation1-4, Profile1-5, Discovery MR450 MR750 and Optima 450w Systems.
- CWA No Power to the Table and Magnet Display, Table Will Not Move And No Lights On the Magnet.
- CWA How to Change Exam Number from Remote Tools.
- Known Software issue with 15M4B coding error.
- Unable to Send Images to the PACS Due to PACS is down.
- U41 of the Slave RF Ctrl Assy, part of the PSU in the SRFD2 RF Amplifier Failed.