Problem Found in 20.1_IB1 Software, Resolved in 20.1_IB2 or 20.1_IB3 Software.
Symptom
Auto Prescan fails with RF Amplifier Duty Cycle Fault. see long description MR450 only. Auto Prescan fails with RF Amplifier Duty Cycle Fault. Auto Prescan fails and/or scanning is paused shortly after the scan begins with a message similar to the following in the Error Log: 2254205 Function: RF: RF Transmit PSD: Spin Echo Coil: HNS Head Scan: 638/3 SRFD2 RF Amplifier Duty Cycle Fault. Unblank duty cycle exceeds 60%.-> This problem generally occurs when using a Spin Echo sequence with Fat Sat pulse, TE = minimum, TR = Auto TR and Xres < 384. Workaround: Observe the value reported on the UI in the Auto TR field. Modify this value by adding 15% and entering the new value in the TR field. Do not modify the number of slices. If problem persists, continually increase TR by 5% until fault no longer appears. An additional option is to increase the Xres to 384 lines or more. This will allow the user to increase resolution at the cost of lower SNR. For complete details refer to service note pages 2 and 3 in Resolution. PR#1759975 Fix: 20.1_IB2 FMI 60787
Error message
2254205 SRFD2 RF Amplifier Duty Cycle Fault. Unblank duty cycle exceeds 60% see long description 2254205 ERROR: EM_RF_SRFD2_ERROR_42 SRFD2 RF Amplifier Duty Cycle Fault. Unblank duty cycle exceeds 60%. Extended Error: Verify proper PSD is used. If PSD is not the problem, perform RF Amplifier Functional Check procedure for SRFD2. UNBLANK Pulse corrupted, check Tyme Board.
Applies to
- Models
- Optima, Discovery
- Product
- Optima MR450W Wide bore magnet. Not Discovery750 or Discovery450.
- Software
- 21.0 Only for Optima MR450W (wide bore) systems. (Not to be used on Discovery MR450 or Discovery MR750). Only for Optima MR450W (wide bore) systems. (Not to be used on Discovery MR450 or Discovery MR750).
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA How to Change Date or Time on LX, Excite, HD, HDe, HDx, HDxT, HFO, Excite HFO, Ovation1-4, Profile1-5, Discovery MR450 MR750 and Optima 450w Systems.
- CWA No Power to the Table and Magnet Display, Table Will Not Move And No Lights On the Magnet.
- CWA How to Change Exam Number from Remote Tools.
- Known Software issue with 15M4B coding error.
- Unable to Send Images to the PACS Due to PACS is down.
- U41 of the Slave RF Ctrl Assy, part of the PSU in the SRFD2 RF Amplifier Failed.