Scan pauses with errors 2261715 and 2261679 due to signal box.
Symptom
Scan pauses with errors 2261715 and 2261679 See long description Scan pauses with the following errors: 2261715 Host: VRH_MRI1Process: NSP File: SCP:CoolingHWOLine: 2942Exception Class: UnknownSeverity: Unknown Function: Power/Support Systems: Heat Exchanger PSD: BRAVOCoil: HNS HeadScan: 25/9Heat Exchanger Cabinet (HEC) detected the gradient coil coolant resistivity has reached an alarm level. Scanning will be inhibited until coolant serviced. Please contact service.-> followed a few seconds later by this error: 2261679 Host: VRH_MRI1Process: NSP File: SCP:CoolingHWOLine: 3098Exception Class: UnknownSeverity: Unknown Function: Power/Support Systems: Heat Exchanger PSD: BRAVOCoil: HNS HeadScan: 25/9Cooling Cabinet does not detect any scan stopping alarms
Error message
2261679 Cooling Cabinet does not detect any scan stopping alarms 2261679 Host: VRH_MRI1Process: NSP File: SCP:CoolingHWOLine: 3098 Exception Class: UnknownSeverity: Unknown Function: Power/Support Systems: Heat Exchanger PSD: BRAVOCoil: HNS HeadScan: 25/9 Cooling Cabinet does not detect any scan stopping alarms 2261715 Heat Exchanger Cabinet (HEC) detected the gradient coil coolant resistivity has reached an alarm level. See Long Description Error: 2261715 Host: lx-mr Process: NSP File: SCP:CoolingHWO Line: 2901 Exception Class: Unknown Severity: Unknown Function: Software/Firmware/Config: N/A PSD: FSE-XL Coil: HDCTL 456 Scan: 521/9 Heat Exchanger Cabinet (HEC) detected the gradient coil coolant resistivity has reached an alarm level. Scanning will be inhibited until coolant serviced. Please contact service.--> Extended Error: Order coolant deionization kit and schedule service. If the resistivity is 0 kOhm-cm, check the wiring between the sensor in the gradient coolant reservoir and the signal box.
Applies to
- Models
- Optima
- Product
- Optima MR450W Wide bore magnet. Not Discovery750 or Discovery450.
- Software
- DV22.0 For the Discovery MR750, MR450 or Optima MR450w products only. For the Discovery MR750, MR450 or Optima MR450w products only.
- Component
- 5269691 Signal Box kit Signal Box kit 5269691
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA How to Change Date or Time on LX, Excite, HD, HDe, HDx, HDxT, HFO, Excite HFO, Ovation1-4, Profile1-5, Discovery MR450 MR750 and Optima 450w Systems.
- CWA No Power to the Table and Magnet Display, Table Will Not Move And No Lights On the Magnet.
- CWA How to Change Exam Number from Remote Tools.
- Known Software issue with 15M4B coding error.
- Unable to Send Images to the PACS Due to PACS is down.
- U41 of the Slave RF Ctrl Assy, part of the PSU in the SRFD2 RF Amplifier Failed.