Scan pauses with errors 2261715 and 2261679 due to signal box.

Symptom

Scan pauses with errors 2261715 and 2261679 See long description Scan pauses with the following errors: 2261715 Host: VRH_MRI1Process: NSP File: SCP:CoolingHWOLine: 2942Exception Class: UnknownSeverity: Unknown Function: Power/Support Systems: Heat Exchanger PSD: BRAVOCoil: HNS HeadScan: 25/9Heat Exchanger Cabinet (HEC) detected the gradient coil coolant resistivity has reached an alarm level. Scanning will be inhibited until coolant serviced. Please contact service.-> followed a few seconds later by this error: 2261679 Host: VRH_MRI1Process: NSP File: SCP:CoolingHWOLine: 3098Exception Class: UnknownSeverity: Unknown Function: Power/Support Systems: Heat Exchanger PSD: BRAVOCoil: HNS HeadScan: 25/9Cooling Cabinet does not detect any scan stopping alarms

Error message

2261679 Cooling Cabinet does not detect any scan stopping alarms 2261679 Host: VRH_MRI1Process: NSP File: SCP:CoolingHWOLine: 3098 Exception Class: UnknownSeverity: Unknown Function: Power/Support Systems: Heat Exchanger PSD: BRAVOCoil: HNS HeadScan: 25/9 Cooling Cabinet does not detect any scan stopping alarms

2261715 Heat Exchanger Cabinet (HEC) detected the gradient coil coolant resistivity has reached an alarm level. See Long Description Error: 2261715 Host: lx-mr Process: NSP File: SCP:CoolingHWO Line: 2901 Exception Class: Unknown Severity: Unknown Function: Software/Firmware/Config: N/A PSD: FSE-XL Coil: HDCTL 456 Scan: 521/9 Heat Exchanger Cabinet (HEC) detected the gradient coil coolant resistivity has reached an alarm level. Scanning will be inhibited until coolant serviced. Please contact service.--> Extended Error: Order coolant deionization kit and schedule service. If the resistivity is 0 kOhm-cm, check the wiring between the sensor in the gradient coolant reservoir and the signal box.

Applies to

Models
Optima
Product
Optima MR450W Wide bore magnet. Not Discovery750 or Discovery450.
Software
DV22.0 For the Discovery MR750, MR450 or Optima MR450w products only. For the Discovery MR750, MR450 or Optima MR450w products only.
Component
5269691 Signal Box kit Signal Box kit 5269691
Area
MR