GE Healthcare · MROptima22742005483002274201
Fails TPS Reset when booting up to Applications or when Resetting TPS due to defective quick disconnect assembly
Symptom
Fails TPS Reset when booting up to Applications or when Resetting TPS See Long Description When the MR system is booting up to applications it will fail TPS reset but Applications will successfully boot. With Applications up and "Reset TPS" has been selected, TPS fails to download successfully.
Error message
2274200 Port detection check failed. The RF Hub hardware detected a port connector, but could not identify it. 2274200Diagnostic: RF Hub Reset Diagnostic Iteration: 1 of 1 Action: 1 Task ID: 0xd0b96c8 Time: 548300 Object: SCP Function: RF: RF Receive Port detection check failed. The RF Hub hardware detected a port connector, but could not identify it. Check cabling and port connectors. Port: Connector P2/1.5T/16 Channels Connector Fault Voltage: 943 mV Expected Voltage Range: 1634 mV - 1755 mV-> Extended Error: The RF Hub detected a resistance on the P connector cable path that was out of the expected range for the connector, system field strength, and system channel count. It could not determine if the range belonged to another connector. Check the coil port cables at the RF Hub RFCB, the LPCA for port P1 or P2 errors, and the electrical docking interface and the cabling in the table for port P3 or P4 errors. Run the Coil Datapath Diagnostic which utilizes the MCRv tool to isolate the problem. Possible cause(s): RF Hub Control Board 2274201 Port detection check failed. The RF Hub hardware detected an invalid or swapped port connector. 2274201Port detection check failed.The RF Hub
Applies to
- Models
- Optima
- Product
- Optima MR450W Wide bore magnet. Not Discovery750 or Discovery450.
- Software
- 21.0 Only for Optima MR450W (wide bore) systems. (Not to be used on Discovery MR450 or Discovery MR750). Only for Optima MR450W (wide bore) systems. (Not to be used on Discovery MR450 or Discovery MR750).
- Component
- 5184208-4 Quick Disconnect Asm 16 Channel P port connector 5184208-4 Quick Disconnect Asm 16 Channel P port connector
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA How to Change Date or Time on LX, Excite, HD, HDe, HDx, HDxT, HFO, Excite HFO, Ovation1-4, Profile1-5, Discovery MR450 MR750 and Optima 450w Systems.
- CWA No Power to the Table and Magnet Display, Table Will Not Move And No Lights On the Magnet.
- CWA How to Change Exam Number from Remote Tools.
- Known Software issue with 15M4B coding error.
- Unable to Send Images to the PACS Due to PACS is down.
- U41 of the Slave RF Ctrl Assy, part of the PSU in the SRFD2 RF Amplifier Failed.